BS EN IEC 62563-2:2021:2022 Edition
$167.15
Medical electrical equipment. Medical image display systems – Acceptance and constancy tests for medical image displays
Published By | Publication Date | Number of Pages |
BSI | 2022 | 40 |
This part of IEC 62563 establishes the performance CRITERIA and test frequencies for the ACCEPTANCE TESTS and CONSTANCY TESTS. The evaluation methods are defined in IEC 62563-1. The scope of this document is directed to practical tests that can be visually evaluated or measured using basic test equipment. This document applies to medical IMAGE DISPLAY SYSTEMS, which can display monochrome image information in the form of greyscale values on colour and greyscale IMAGE DISPLAY SYSTEMS. This document does not apply to information displays and to displays used solely for control of technical settings of all medical information.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
6 | English CONTENTS |
8 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms, definitions, symbols and abbreviated terms 3.1 Terms and definitions |
12 | 3.2 Symbols Tables Table 1 ā Overview to the definitions of physical parameters |
13 | 3.3 Abbreviated terms 4 General |
14 | 5 Categories |
15 | 6 ACCEPTANCE TEST 6.1 General 6.2 When to test 6.3 Evaluation items and criteria for acceptance test Table 2 ā Tests and test items for quantitative evaluation |
17 | Table 3 ā Tests and test items for visual evaluation |
18 | Table 4 ā Quantitative acceptance and constancy tests |
19 | 6.4 Acceptance test result Table 5 ā Visual acceptance and constancy tests |
20 | 7 CONSTANCY TEST 7.1 General 7.2 Frequency of constancy test 7.3 Evaluation items and criteria 7.4 Constancy test result |
21 | Annex A (informative)Sample test reports A.1 General A.2 Acceptance test sample report of a category I-A diagnostic display A.2.1 General information A.2.2 Displays A.2.3 Test results |
25 | A.3 Constancy test sample report of a category I-A diagnostic display A.3.1 General information A.3.2 Displays A.3.3 Test results |
28 | Annex B (informative)Ambient light control Figures Figure B.1 ā Lmin and E relationship when r’ ā„ 250 |
30 | Figure B.2 ā Possible deviation range of E conforming to GSDF Ā±10 % |
31 | Figure B.3 (1 of 2) ā Example charts of possible deviation ranges of illuminance (E), calibrated at four different ambient luminance (Lamb) levels (shown at right) |
32 | Figure B.3 (2 of 2) ā Example charts of possible deviation ranges of ILLUMINANCE (E ),calibrated at four different ambient LUMINANCE (L amb) levels (shown at right) |
33 | Annex C (informative)Evaluation criteria examples of clinical images C.1 General C.2 Chest image Figure C.1 ā Chest clinical image |
34 | Figure C.2 ā Visually sharp reproduction of the vessel from hilum to peripheral area Figure C.3 ā Visibility of vessels under retro-cardiac area and under diaphragm |
35 | Figure C.4 ā Visually sharp reproduction of trachea and proximal bronchia Figure C.5 ā Distinct reproduction of frame of spine, lateral protrusion, and spinous process Figure C.6 ā Distinct reproduction of edge of heart |
36 | Figure C.7 ā Excellent graininess (no artefacts or significant noise) of thorax and underarm soft tissue |
37 | Figure C.8 ā Distinct reproduction of the border of rib and peripheral lung, border of lower edge of lung |
38 | Bibliography |
39 | Index of defined terms |