{"id":248296,"date":"2024-10-19T16:21:22","date_gmt":"2024-10-19T16:21:22","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60793-2-102017\/"},"modified":"2024-10-25T11:30:35","modified_gmt":"2024-10-25T11:30:35","slug":"bs-en-60793-2-102017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60793-2-102017\/","title":{"rendered":"BS EN 60793-2-10:2017"},"content":{"rendered":"
This part of IEC 60793<\/span> <\/span> is applicable to optical fibre sub-categories A1a, A1b, and A1d. These fibres are used or can be incorporated in information transmission equipment and optical fibre cables.<\/p>\n Sub-category A1a applies to 50\/125 \u00b5m graded index fibre. Four bandwidth grades are defined as models A1a.1, A1a.2, A1a.3 and A1a.4. Each of these bandwidth grades is defined for two levels of macrobend loss performance that are distinguished by “a” or “b” suffix. Those models with suffix “a” are specified to meet traditional macrobend loss performance levels. Those models with suffix “b” are specified to meet enhanced macrobend loss (i.e. lower loss) performance levels. Model A1a.4 supports single wavelength or multi-wavelength transmission systems in the vicinity of 850 nm to 950 nm.<\/p>\n Sub-category A1b applies to 62,5\/125 \u00b5m graded index fibre and sub-category A1d applies to 100\/140 \u00b5m graded index fibre.<\/p>\n Other applications include, but are not restricted to, the following: short reach, high bit-rate systems in telephony, distribution and local networks carrying data, voice and\/or video services; on-premises intra-building and inter-building fibre installations including data centres, local area networks (LANs), storage area networks (SANs), private branch exchanges (PBXs), video, various multiplexing uses, outside telephone cable plant use, and miscellaneous related uses.<\/p>\n Three types of requirements apply to these fibres:<\/p>\n general requirements, as defined in IEC 60793\u20112<\/span> <\/span>;<\/p>\n<\/li>\n specific requirements common to the category A1 multimode fibres covered in this document and which are given in Clause 5<\/span>;<\/p>\n<\/li>\n particular requirements applicable to individual fibre sub-categories and models, or specific applications, which are defined in the normative specification annexes.<\/p>\n<\/li>\n<\/ul>\n Optical fibres – Product specifications. Sectional specification for category A1 multimode fibres<\/b><\/p>\n\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 7<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 10<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 12<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 13<\/td>\n 3 Terms, definitions
4 Abbreviated terms <\/td>\n<\/tr>\n\n 14<\/td>\n 5 Specifications
5.1 General
5.2 Dimensional requirements
Tables
Table 1 \u2013 Dimensional attributes and measurement methods <\/td>\n<\/tr>\n\n 15<\/td>\n 5.3 Mechanical requirements
Table 2 \u2013 Dimensional requirements common to category A1 fibres
Table 3 \u2013 Additional dimensional attributes required in sub-category specifications
Table 4 \u2013 Mechanical attributes and measurement methods <\/td>\n<\/tr>\n\n 16<\/td>\n 5.4 Transmission requirements
Table 5 \u2013 Mechanical requirements common to category A1 fibres
Table 6 \u2013 Transmission attributes and measurement methods <\/td>\n<\/tr>\n\n 17<\/td>\n Table 7 \u2013 Additional transmission attributes required in sub-category specifications <\/td>\n<\/tr>\n \n 18<\/td>\n 5.5 Environmental requirements
5.5.1 General
Figures
Figure 1 \u2013 Relation between bandwidths at 850 nm and 1 300 nm
Table 8 \u2013 Environmental exposure tests
Table 9 \u2013 Attributes measured for environmental tests <\/td>\n<\/tr>\n\n 19<\/td>\n 5.5.2 Mechanical environmental requirements (common to all fibres in category A1)
5.5.3 Transmission environmental requirements
Table 10 \u2013 Strip force for environmental tests
Table 11 \u2013 Tensile strength for environmental tests
Table 12 \u2013 Stress corrosion susceptibility for environmental tests <\/td>\n<\/tr>\n\n 20<\/td>\n Table 13 \u2013 Change in attenuation for environmental tests <\/td>\n<\/tr>\n \n 21<\/td>\n Annex A (normative)Specifications for sub-category A1a multimode fibres
A.1 General
A.2 Dimensional requirements
Table A.1 \u2013 Dimensional requirements specific to A1a fibres <\/td>\n<\/tr>\n\n 22<\/td>\n A.3 Mechanical requirements
A.4 Transmission requirements
Table A.2 \u2013 Mechanical requirements specific to A1a fibres <\/td>\n<\/tr>\n\n 23<\/td>\n A.5 Environmental requirements
Table A.3 \u2013 Transmission requirements specific to A1a fibres <\/td>\n<\/tr>\n\n 24<\/td>\n Annex B (normative)Specifications for sub-category A1b multimode fibres
B.1 General
B.2 Dimensional requirements
B.3 Mechanical requirements
B.4 Transmission requirements
Table B.1 \u2013 Dimensional requirements specific to A1b fibres
Table B.2 \u2013 Mechanical requirements specific to A1b fibres <\/td>\n<\/tr>\n\n 25<\/td>\n B.5 Environmental requirements
Table B.3 \u2013 Transmission requirements specific to A1b fibres <\/td>\n<\/tr>\n\n 26<\/td>\n Annex C (normative)Specifications for sub-category A1d multimode fibres
C.1 General
C.2 Dimensional requirements
C.3 Mechanical requirements
C.4 Transmission requirements
Table C.1 \u2013 Dimensional requirements specific to A1d fibres
Table C.2 \u2013 Mechanical requirements specific to A1d fibres <\/td>\n<\/tr>\n\n 27<\/td>\n C.5 Environmental requirements
Table C.3 \u2013 Transmission requirements specific to A1d fibres <\/td>\n<\/tr>\n\n 28<\/td>\n Annex D (normative)Fibre differential mode delay (DMD), calculatedeffective modal bandwidth (EMBc) and calculated overfilled modal bandwidth (OMBc) requirements
D.1 A1a.2 fibre DMD requirements
D.1.1 General
D.1.2 DMD templates
Table D.1 \u2013 DMD templates for A1a.2 fibres <\/td>\n<\/tr>\n\n 29<\/td>\n D.1.3 DMD interval masks
Figure D.1 \u2013 DMD template requirements <\/td>\n<\/tr>\n\n 30<\/td>\n D.2 A1a.2 fibre EMBc requirements
D.2.1 General
D.2.2 Calculated effective bandwidth
Table D.2 \u2013 DMD interval masks for A1a.2 fibres <\/td>\n<\/tr>\n\n 31<\/td>\n Table D.3 \u2013 DMD weightings <\/td>\n<\/tr>\n \n 32<\/td>\n D.3 A1a.3 DMD requirements
D.3.1 General
D.3.2 DMD templates <\/td>\n<\/tr>\n\n 33<\/td>\n D.3.3 DMD interval masks
D.4 A1a.3 fibre EMBc requirements
D.4.1 General
D.4.2 Calculated effective bandwidth
D.5 A1a.4 fibre modal bandwidth requirements
D.5.1 General
D.5.2 Calculated effective modal bandwidth
Table D.4 \u2013 DMD templates for A1a.3 fibres
Table D.5 \u2013 DMD interval masks for A1a.3 fibres <\/td>\n<\/tr>\n\n 34<\/td>\n D.5.3 Calculated overfilled modal bandwidth
Table D.6 \u2013 DMD weighting for OMBc <\/td>\n<\/tr>\n\n 35<\/td>\n Annex E (informative)System, modal bandwidth, and transmitter considerations
E.1 Background
E.2 System considerations
E.2.1 A1a.2 and A1a.3 fibres
E.2.2 A1a.4 fibre <\/td>\n<\/tr>\n\n 36<\/td>\n E.3 Effective modal bandwidth (EMB) <\/td>\n<\/tr>\n \n 37<\/td>\n E.4 Transmitter encircled flux (EF) and centre wavelength requirements
E.4.1 Encircled flux
Figure E.1 \u2013 Estimated minimum wide band EMB versus wavelength <\/td>\n<\/tr>\n\n 38<\/td>\n E.4.2 Centre wavelength for A1a.2 and A1a.3 fibres
E.4.3 Centre wavelength for A1a.4 fibre
Figure E.2 \u2013 Approximate position of DMD weightings relative to the EF boundaries of Equations (E.6) and (E.7) <\/td>\n<\/tr>\n\n 39<\/td>\n Annex F (informative)Bandwidth nomenclature explanation
Table F.1 \u2013 Bandwidth nomenclature explanation <\/td>\n<\/tr>\n\n 40<\/td>\n Annex G (informative)Preliminary indications for items needing further study
G.1 Effective modal bandwidth (EMB) at 1 300 nm
G.2 Scaling of EMB with DMD <\/td>\n<\/tr>\n\n 42<\/td>\n Annex H (informative)Applications and cabling categories supported by A1 fibres
H.1 Standardised applications
H.2 Cross reference of cabled optical fibre performance categories in ISO\/IEC 11801-1 to fibres of this document
Table H.1 \u2013 Some standardised applications supported byA1a fibres and in some cases A1b fibres <\/td>\n<\/tr>\n\n 43<\/td>\n Table H.2 \u2013 Cross reference between ISO\/IEC 11801-1 and this document <\/td>\n<\/tr>\n \n 44<\/td>\n Annex I (informative)1-Gigabit, 10-Gigabit, 25-Gigabit, 40-Gigabit and 100-Gigabit Ethernet applications <\/td>\n<\/tr>\n \n 45<\/td>\n Table I.1 \u2013 Summary of 1 Gb\/s, 10 Gb\/s, 25 Gb\/s, 40 Gb\/s and 100 Gb\/s Ethernet requirements and capabilities <\/td>\n<\/tr>\n \n 49<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2017<\/td>\n 52<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":248304,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[649,2641],"product_tag":[],"class_list":{"0":"post-248296","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-180-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/248296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/248304"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=248296"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=248296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=248296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}