ASME BPVC IV 2015
$377.00
ASME BPVC – IV -2015 BPVC Section IV, Rules for Construction of Heating Boilers
Published By | Publication Date | Number of Pages |
ASME | 2015 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
49 | HG-307 Some Acceptable Types of Unstayed Flat Heads and Covers |
53 | HG-309 Spherically Dished Steel Plate Covers With Bolting Flanges |
55 | HG-312.4 Acceptable Type of Ring-Reinforced Furnace |
56 | HG-312.7 Connection Between Plain and Corrugated Furnace |
57 | HG-312.8 Acceptable Type of Semicircular Furnace Reinforcement |
59 | HG-321 Chart for Determining Values of F HG-321 Values of Spherical Radius Factor K1 |
62 | HG-326.1 Some Representative Configurations Describing the Reinforcement Dimension, te, and the Finished Opening Dimension, d |
63 | HG-326.2 Nomenclature and Formulas for Reinforced Openings |
65 | HG-340.1 Pitch of Staybolts Adjacent to Upper Corners of Fireboxes HG-340.2 Acceptable Proportions for Ends of Through‐Stays |
66 | HG-340.3 Examples of Acceptable Corner Welds for Pressures Not Over 30 psi |
67 | HG-340 Allowable Pitch of Stays, in. (mm) (Limited by HG-340.3) |
69 | HG-343 Details of Installation of Diagonal Stays |
70 | HG-345.1(a) Sketch Showing Application of HG-345.1 to the Staying of Boilers |
71 | HG-345.1(b) Sketch Showing Application of HG-345.1 to the Staying of Boilers |
72 | HG-350.1 Example of Tube Spacing With Pitch of Holes Equal in Every Row HG-350.2 Example of Tube Spacing With Pitch of Holes Unequal in Every Second Row |
73 | HG-350.3 Example of Tube Spacing With Pitch of Holes Varying in Every Second and Third Row HG-350.4 Example of Tube Spacing With Tube Holes on Diagonal Lines |
74 | HG-360 Permitted O‐Ring Materials |
75 | HG-370 Minimum Thickness of Material for Threaded Connections to Boilers |
79 | HG-402 Official Certification Mark to Denote the American Society of Mechanical Engineers’ Standard |
88 | HG-530.1 Official Certification Mark to Denote the American Society of Mechanical Engineers’ Standard |
89 | HG-530.2 Steam and Water Boilers Form of Marking on Completed Boilers or Their Nameplates HG-530.3 Boilers Suitable for Water Only |
90 | HG-530.4 Steam and Water Boilers HG-530.5 Boilers Suitable for Water Only |
91 | HG-530.6 Boilers Suitable for Water Only HG-530.7 Steam and Water Boilers |
92 | HG-530.8 Boilers Suitable for Water Only |
102 | HG-703.1(a) Steam Boilers in Battery ‐ Pumped Return ‐ Acceptable Piping Installation |
103 | HG-703.1(b) Steam Boilers in Battery ‐ Gravity Return ‐ Acceptable Piping Installation |
104 | HG-703.2 Hot Water Boilers in Battery ‐ Acceptable Piping Installation |
106 | HG-709.2 Expansion Tank Capacities for Forced Hot Water Systems |
107 | HG-715 Size of Bottom Blowoff Piping, Valves, and Cocks |
108 | HG-725(a) Spacing and Weld Details for Supporting Lugs in Pairs on Horizontal‐Return Tubular Boiler |
109 | HG-725(b) Welded Bracket Connection for Horizontal‐Return Tubular Boiler |
116 | HF-300.1 Maximum Allowable Stress Values for Ferrous Materials, ksi |
122 | HF-300.1M Maximum Allowable Stress Values for Ferrous Materials, MPa |
128 | HF-300.2 Maximum Allowable Stress Values for Nonferrous Materials, ksi |
133 | HF-300.2M Maximum Allowable Stress Values for Nonferrous Materials, MPa |
141 | HW-701.1 Butt Welding of Plates of Unequal Thickness |
143 | HW-701.3 Some Forms of Attachments of Pressure Parts to Flat Plates to Form a Corner Joint (Tee Joint) |
144 | HW-710.4(a) Some Acceptable Types of Diagonal Stays for Installation by Welding HW-710.4(b) Unacceptable Types of Diagonal Stays for Installation by Welding |
146 | HW-715.1 Heads Attached to Shells HW-713 Firetube Extension Through Tubesheets for Welded Construction |
148 | HW-731 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells, Drums, and Headers |
151 | HW-740 Three‐Ply Joint Assemblies |
153 | HW-745 Two‐Ply Joint Assemblies |
163 | HB-1305 Recommended Joint Clearances at Brazing Temperature |
168 | HC-204.1 Dimensions of Tensile Test Specimen HC-205.1 Cast Test Bars |
170 | HC-212 Correction Factors for Transverse Test Bars HC-214 Pipe Plug Size for Minimum Wall Thickness |
172 | HC-300 Maximum Allowable Stress Values in Tension for Cast Iron, ksi (MPa) |
173 | HC-311 Spherically Shaped Covers With Bolting Flanges |
198 | HLW-300 Maximum Allowable Stress Values in Tension for Lined Water Heater Materials, ksi (MPa) |
200 | HLW-301 Maximum Allowable Stress Values in Tension for Unlined Water Heater Materials ksi (MPa) |
204 | HLW-401.1 Butt Welding of Plates of Unequal Thickness |
205 | HLW-401.2 Typical Corner Joints |
206 | HLW-411 Typical Water Heater Welded Joints |
208 | HLW-413 Tubes Attached by Welding |
210 | HLW-415 Heads Attached to Shells |
211 | HLW-431.1 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells and Head |
213 | HLW-431.5 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells and Head |
215 | HLW-432.1 Some Acceptable Types of Brazed Fittings, Nozzles, and Other Connections to Copper‐Lined Shells and Heads |
221 | HLW-602.1 Official Symbol to Denote The American Society of Mechanical Engineers’ Standard HLW-602.2 Form of Stamping on Completed Water Heaters |
225 | HLW-809.1 Expansion Tank Capacities for a Water Heater |
226 | HLW-809.1 A Typical Acceptable Piping Installation for Storage Water Heaters in Battery |
227 | HLW-809.2 A Typical Acceptable Piping Installation for Flow Through Water Heater With Provisions for Piping Expansion |
228 | Table 2-100 Codes, Standards, and Specifications Referenced in Text 2-100 Codes, Standards, and Specifications Referenced in Text |
232 | Table 4-1 Guide for the Preparation of Section IV Manufacturer’s Data Report Forms 4-1 Guide for the Preparation of Section IV Manufacturer’s Data Report Forms |
236 | FORM H-2 MANUFACTURER’S DATA REPORT FOR ALL TYPES OF BOILERSEXCEPT WATERTUBE AND THOSE MADE OF CAST IRON H-2 Manufacturer’s Data Report for all Types of Boilers Except Watertube and those Made of Cast Iron |
238 | FORM H-3 MANUFACTURER’S DATA REPORT FOR WATERTUBE BOILERS H-3 Manufacturer’s Data Report for Watertube Boilers |
240 | FORM H-4 MANUFACTURER’S PARTIAL DATA REPORT H-4 Manufacturer’s Partial Data Report |
242 | FORM H-5 MANUFACTURER’S MASTER DATA REPORT FOR BOILERS CONSTRUCTED FROM CAST IRON H-5 Manufacturer’s Master Data Report for Boilers Constructed from Cast Iron |
244 | FORM H-5A MANUFACTURER’S MASTER DATA REPORT FOR BOILERS CONSTRUCTED FROM CAST ALUMINUM H-5A Manufacturer’s Master Data Report for Boilers Constructed from Cast Aluminum |
246 | FORM H-6 MANUFACTURER’S DATA REPORT SUPPLEMENTARY SHEET H-6 Manufacturer’s Data Report Supplementary Sheet |
247 | FORM HC-1 MANUFACTURER’S MATERIAL CERTIFICATE OF CONFORMANCE FOR CAST IRON BOILER SECTIONS HC-1 Manufacturer’s Material Certificate of Conformance for Cast Iron Boiler Sections |
248 | FORM HC-2 MANUFACTURER’S MATERIAL CERTIFICATE OF CONFORMANCE FOR HYDROSTATIC TESTING OF CAST IRON BOILER SECTIONS HC-2 Manufacturer’s Material Certificate of Conformance for Hydrostatic Testing of Cast Iron Boiler Sections |
249 | FORM HA-1 MANUFACTURER’S MATERIAL CERTIFICATE OF CONFORMANCE FOR CAST ALUMINUM BOILER SECTIONS HA-1 Manufacturer’s Material Certificate of Conformance for Cast Aluminum Boiler Sections |
250 | FORM HA-2 MANUFACTURER’S MATERIAL CERTIFICATE OF CONFORMANCE FOR HYSTROSTATIC TESTING OF CAST ALUMINUM BOILER SECTIONS HA-2 Manufacturer’s Material Certificate of Conformance for Hydrostatic Testing of Cast Aluminum Boiler Sections |
251 | FORM HLW-6 MANUFACTURER’S DATA REPORT FOR WATER HEATERS OR STORAGE TANKS HLW-6 Manufacturer’s Data Report for Water Heaters or Storage Tanks |
253 | FORM HLW-7 MANUFACTURER’S PARTIAL DATA REPORT FOR WATER HEATERSAND STORAGE TANKS HLW-7 Manufacturer’s Partial Data Report for Water Heaters and Storage Tanks |
255 | FORM HLW-8 MANUFACTURER’S MASTER DATA PROOF TEST REPORT FOR WATER HEATERS OR STORAGE TANKS HLW-8 Manufacturer’s Master Data Proof Test Report for Water Heaters or Storage Tanks |
258 | Table 6-1 Standard Units for Use in Equations 6-1 Standard Units for Use in Equations |
262 | FORM 8-1 CERTIFICATE OF CONFORMANCE FOR REAPPLICATION OF THE CERTIFICATION MARK 8-1 Certificate of Conformance for Reapplication of the Certification Mark |
263 | Table 8-200-1 Guide for Completing the Certificate of Conformance for Reapplication of the Certification Mark 8-200-1 Guide for Completing the Certificate of Conformance for Reapplication of the Certification Mark |
266 | Table A-100 Guide for Estimating Steaming Capacity Based on Heating Surface A-100 Guide for Estimating Steaming Capacity Based on Heating Surface |
271 | Figure D-100 Computation of Typical Pad Reinforcement D-100 Computation of Typical Pad Reinforcement |
272 | Figure D-101 Computation of a Typical Nozzle Fitting D-101 Computation of a Typical Nozzle Fitting |
284 | Figure K-1 Sample Certificate of Authorization K-1 Sample Certificate of Authorization |
289 | Table N-1 Guide for the Preparation of Section IV Manufacturer’s Certificate of Conformance Form HV-1 N-1 Guide for the Preparation of Section IV Manufacturer’s Certificate of Conformance Form HV-1 |
290 | FORM HV-1 MANUFACTURER’S CERTIFICATE OF CONFORMANCE FOR PRESSURE RELIEF VALVES HV-1 Manufacturer’s Certificate of Conformance for Pressure Relief Valves |
296 | INTERPRETATIONS VOLUME 63 — SECTION IV |