C1075-10 Standard Practices for Sampling Uranium-Ore Concentrate

Published By Publication Date Number of Pages
ASTM 2010 10
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

1.1 These practices are intended to provide the nuclear industry with procedures for obtaining representative bulk samples from uranium-ore concentrates (UOC) (see Specification C967 ).

1.2 These practices also provide for obtaining a series of representative secondary samples from the original bulk sample for the determination of moisture and other test purposes, and for the preparation of pulverized analytical samples (see Test Methods C1022 ).

1.3 These practices consist of a number of alternative procedures for sampling and sample preparation which have been shown to be satisfactory through long experience in the nuclear industry. These procedures are described in the following order.

1.3.1 The primary and secondary sampling stages can be organized in the following way:

1.3.2 It is possible to combine the various elements of these stages in different ways to give satisfactory results depending on the agreed requirements of the contracting parties. For a given stage, however, each procedure must be regarded as a whole. It is highly inadvisable to mix elements belonging to different procedures.

1.4 These procedures do not include requirements for health, safety, and accountability. The observance of these practices does not relieve the user of the obligation to be aware of and to conform to all applicable international, federal, state, and local regulations pertaining to processing, shipping, or using uranium-ore concentrates. (Guidance is provided in CFR 10, Chapter 1.)

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
General Requirements
2 Primary Sampling, Falling Streamā€”1 % In One Stage
FIG. 1
3 Primary Sampling, Falling Streamā€”1 % In Two Stages
FIG. 2
4 Primary Samplingā€”Auger Sampling Procedure
5 Secondary Samplingā€”Straight-Path (Reciprocating) Cutter
Secondary Samplingā€”Rotating (Vezin) Cutter
FIG. 3
6 FIG. 4
FIG. 5
7 Secondary Samplingā€”Rotating (Vezin) Cutter Multi-Sampler
Sample Preparation
FIG. 6
8 Scope
Procedure
Unground Samples
Scope
Procedure
Unground Samples
Scope
Procedure
9 Sample Packaging
Wax Sealing
Vacuum Sealing
Sample Use
Keywords
10 X1. AUGER SAMPLER RANDOM POSITIONS