ASTM-C791:2011 Edition
$58.50
C791-11 Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Boron Carbide
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 25 |
ASTM C791-11
Historical Standard: Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Boron Carbide
ASTM C791
Scope
1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications.
1.2 The analytical procedures appear in the following order:
7.1 This method covers the determination of total carbon in nuclear-grade boron carbide in either powder or pellet form.
17.1 This method covers the determination of total boron in samples of boron carbide powder and pellets by titrimetry and ICP OES. The recommended amount of boron for each titration is 100 Ā± 10 mg.
28.1 This method covers the determination of the isotopic composition of boron in nuclear-grade boron carbide, in powder and pellet form, containing natural to highly enriched boron.
33.1 This method covers the separation of up to 100 Ī¼g of halides per gram of boron carbide. The separated halides are measured using other methods found in this standard. It also covers the sample preparation for the determination of isotopic composition by ICP MS.
41.1 This method covers the measurement of chloride after separation from boron carbide by pyrohydrolysis. The lower limit of the method is about 2 Ī¼g of chloride per titration.
50.1 This method covers the measurement of chloride and fluoride after separation from boron carbide by pyrohydrolysis. The limit of detection for chloride and fluoride in the boron carbide sample is 3 mg/kg and 2 mg/kg, respectively.
60.1 This method covers the determination of water in boron carbide in either powder or pellet form. The lower limit of the method is 5 Ī¼g of water. The lower limit of the weight loss on drying method is 20 mg/kg for a sample mass of 5 g.
65.1 This method covers the determination of soluble boron in boron carbide. Soluble boron is defined as that boron dissolved under the conditions of the test.
80.1 This method covers the determination of free carbon (also called soluble carbon) in boron carbide powders and shaped or sintered bodies of boron carbide after crushing. This method is applicable to mass fractions of free carbon of 0.01 % to 10 %.
Keywords
Boron carbide (nuclear grade); Carbon content–nuclear materials; Chloride analysis–nuclear applications; Fluoride content; Isotopic analysis; Mass spectrometry–nuclear materials/applications; Spectrochemical analysis; Trace elements–nuclear materials; Trace elements–spectrochemical analysis; Water content
ICS Code
ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
DOI: 10.1520/C0791-11
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Significance and Use Reagents Safety Precautions Sampling |
2 | Scope Summary of Test Method Interferences Apparatus Reagents Sampling and Sample Preparation Calibration Procedure |
3 | Calculation ( ) Scope Summary of Method Interferences Apparatus |
4 | Reagents Precautions Sampling and Sample Preparation Procedure |
5 | Titrimetric Determination of Boron |
6 | ICP OES |
7 | Precision and Bias Scope Summary of Method Interferences Isotopic Composition by TIMS |
8 | Isotopic Composition by ICP MS |
9 | Scope Summary of Method Interferences Apparatus Reagents Precautions Procedure |
10 | Pyrohydrolysis as Sample Preparation Procedure for Isotipic Composition by ICP MS Scope Summary of Method |
11 | Interferences Apparatus Reagents Calibration of Titrator Procedure Calculation Precision and Accuracy Scope Summary of Method Interferences |
12 | Apparatus Reagents Calibration of Electrode Procedure Calculation Precision and Accuracy Preface |
13 | Scope Water by Constant-Voltage Coulometry |
14 | Weight Loss on Drying Method DCArc OES Method |
16 | Wet Chemical Methods |
17 | Scope Summary of Method Interferences Apparatus |
18 | Reagents Precautions Standardization of Titrant Blank Sample Preparation Procedure |
19 | Calculation Procedure Calculation Precision and Bias |
20 | Determination of Soluble Boron by ICP OES Scope Summary of Method Interferences Apparatus |
21 | Reagents Sample Preparation Calibration Procedure Calculation of Free Carbon Content |
22 | Precision and Bias REFERENCES |
23 | TABLE 1 FIG. 1 FIG. 2 |
24 | FIG. 3 |
25 | FIG. 4 |