BS 4592-6:2008
$86.31
Industrial type flooring and stair treads – Glass reinforced plastics (GRP) moulded open mesh gratings and protective barriers. Specification
Published By | Publication Date | Number of Pages |
BSI | 2008 | 12 |
This part of BS 4592 specifies requirements for the design, manufacture, supply and installation of glass reinforced plastics (GRP) moulded open mesh gratings intended for industrial flooring, walkways and stair treads.
It is not applicable where access to machinery is required, in which case the requirements of BS EN ISO 14122 apply.
NOTE For the common requirements for industrial flooring and stair treads, see BS 4592-0.
In addition to the definitive requirements, this standard also requires the items detailed in BS 4592-0:2006, Clause 4 to be documented. For compliance with this standard, both the definitive requirements and the documented items have to be satisfied.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | Contents 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Information to be supplied 3 5 Material requirements 3 6 Dimensional and manufacturing tolerances 4 7 Installed panels 5 8 Structural performance requirements 5 Bibliography 7 List of figures Figure 1 – Grating terms 2 List of tables Table 1 – Permissible grating panel size tolerances 4 Table 2 – Manufacturing tolerances 4 |
4 | Foreword |
5 | 1 Scope 2 Normative references 3 Terms and definitions 3.1 General terms |
6 | Figure 1 Grating terms |
7 | 3.2 Dimensions of grating panels 4 Information to be supplied 5 Material requirements |
8 | 6 Dimensional and manufacturing tolerances 6.1 General Table 1 Permissible grating panel size tolerances Table 2 Manufacturing tolerances |
9 | 6.2 Moulded open mesh grating 7 Installed panels 8 Structural performance requirements 8.1 General 8.2 Flooring and walkways a) It shall have a load safety factor, for dead and imposed loads, of not less than 4.0 when subjected to the unfactored imposed load given in BS 4592-0:2006, Table 1. b) It shall deflect elastically by not more than 1/200 times the effective span or 10 mm, whichever is the least amount, when subjected to the unfactored imposed load given in BS 4592-0:2006, Table 1. |
10 | 8.3 Stair treads 8.4 Protective barriers |
11 | Bibliography |