BS EN 1364-1:2015

$189.07

Fire resistance tests for non-loadbearing elements – Walls

Published By Publication Date Number of Pages
BSI 2015 50
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European standard specifies a method for determining the fire resistance of non-loadbearing walls.

This European Standard is used in conjunction with EN 1363‑1 .

It is applicable to internal non-loadbearing walls (partitions), with and without glazing, non-loadbearing walls consisting almost wholly of glazing (glazed non-loadbearing walls) and other non-loadbearing internal and external non-loadbearing walls with and without glazing.

The fire resistance of external non-loadbearing walls can be determined under internal or external exposure conditions. In the latter case the external fire exposure curve given in EN 1363‑2 is used.

It is not applicable to:

  1. curtain walls (external non-loadbearing walls suspended in front of the floor slab), unless explicitly permitted under EN 1364‑3 or EN 1364‑4 which contain details of the methodology to be used.

  2. non-loadbearing walls containing door assemblies that are tested according to EN 1634‑1 .

Specific requirements for testing glazed elements or non-loadbearing walls incorporating glazing are given in Annex A.

Specific requirements relating to the testing of non-loadbearing external and internal walls designed to span horizontally between two independently proven fire resisting vertical structural elements are given in Annex B.

PDF Catalog

PDF Pages PDF Title
7 European foreword
8 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
11 4 Test equipment
5 Test conditions
6 Test specimen
6.1 Size
6.2 Number
6.3 Design
6.3.1 General
12 6.3.2 Vertical joints
6.3.3 Horizontal joints
6.3.4 Restraint
13 6.4 Construction
6.5 Verification
7 Installation of test specimen
7.1 General
7.2 Supporting construction
8 Conditioning
14 9 Application of instrumentation
9.1 Thermocouples
9.1.1 Furnace thermocouples (plate thermometers)
9.1.2 Unexposed face thermocouples
9.1.2.1 General
9.1.2.2 Average temperature
9.1.2.3 Maximum temperature
15 9.2 Pressure
9.3 Deflection
9.4 Radiation
9.5 Impact
10 Test procedure
11 Performance criteria
12 Test report
16 13 Field of direct application of test results
13.1 General
13.2 Extension of width
13.3 Extension of height
17 13.4 Supporting constructions
13.4.1 Standard supporting constructions
13.4.2 Non-standard supporting constructions
18 Figure 1 ( Position of free edge and joints (see 6.3.2 and 6.3.3 and A.2)
19 Figure 2 ( Example of unexposed thermocouple positions and deflection measurement positions for masonry walls
20 Figure 3 ( Example of unexposed thermocouple positions for masonry walls
38 Annex A (normative) Specific requirements for testing glazed elements or non-loadbearing walls incorporating glazing
A.1 General
A.2 Test specimen design
39 A.3 Test specimen instrumentation
A.3.1 General
A.3.2 Average temperature rise
A.3.2.1 Fully glazed test specimen
A.3.2.2 Partly glazed test specimen
A.3.3 Maximum temperature rise
40 A.3.4 Radiation measurement
A.3.5 Deflection measurement
A.4 Field of direct application of test results
A.4.1 General
A.4.2 Field of direct application rules not requiring overrun time
A.4.2.1 Glazed element
A.4.2.1.1 Installation angle
41 A.4.2.1.2 Height of the glazed element
A.4.2.1.3 Width of the glazed element
A.4.2.2 Glazing system (see Figure 16)
A.4.2.2.1 Linear dimensions
A.4.2.2.2 Aspect ratio
42 A.4.2.2.3 Glazing beads
A.4.2.3 Framing system (see Figure 16)
A.4.2.4 Supporting constructions
A.4.2.4.1 General
A.4.2.4.2 Standard supporting constructions
43 A.4.2.4.3 Non-standard supporting construction
A.4.3 Field of direct application rules requiring overrun time
A.4.3.1 General
Table A.1 ( Overrun time
A.4.3.2 Dimensions of the glazed element
A.4.3.2.1 Height
A.4.3.2.2 Width
44 A.4.3.3 Dimensions and area of individual rectangular glass panes
A.4.3.4 Aspect ratio
A.4.3.5 Area of individual circular, triangular and four side non-rectangular glass panes
45 Annex B (normative) Specific requirements for testing non-loadbearing external and internal walls designed to span horizontally between two independently proven fire resisting vertical structural elements
B.1 General
B.2 Test specimen
B.2.1 Size
B.2.2 Number
B.2.3 Design
B.2.4 Boundary and Restraint conditions
46 B.3 Test specimen instrumentation
B.4 Test procedure
B.5 Performance criteria
B.6 Field of direct application of test results
B.6.1 General
47 B.6.2 Supporting constructions
B.6.3 Extension of width
B.6.4 Extension of height
48 Bibliography
BS EN 1364-1:2015