BS EN 1397:2021 – TC:2022 Edition
$217.84
Tracked Changes. Heat exchangers. Hydronic room fan coil units. Test procedures for establishing the performance
Published By | Publication Date | Number of Pages |
BSI | 2022 | 82 |
This document applies to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating.
This document covers both air free delivery and air ducted units with a maximum external static pressure due to duct resistance of 120 Pa max.
This document applies to all types of fan speed control of a fan coil unit (variable speed, multispeed).
This document deals with the cooling and heating functions of the FCU considered as an emitter for cooling/heating of a room/space. It does not cover any ventilation function of the unit.
If the FCU can also provide fresh air, this function is not considered and the fresh air inlet closed during testing.
This document provides a method for the determination of the thermal performance of fan coil units in standard conditions, for the use with hot or chilled water or water mixtures. The test procedures given in this standard may additionally be used for determining performance at other conditions.
It also provides the method for the determination of the air flow rate supplied by the fan coil unit.
This document does not cover the rating of heating or cooling from direct expansion coils or heating from electric resistance elements.
This document does not cover acoustic performance of fan coil units which is dealt with in EN 16583 .
It is not the purpose of this document to specify the tests used for production or field testing.
For the purpose of remaining clauses, the term “unit” is used to mean “fan coil unit” as defined in 3.1.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30447118 |
49 | A-30409061 |
50 | National foreword |
54 | Annex ZA (informative) Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 2016/2281 (OJEU L346/1-50, 20.12.2016) aimed to be covered Annex ZA (informative) Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 2016/2281 (OJEU L346/1-50, 20.12.2016) aimed to be covered |
57 | European foreword |
58 | 1 Scope 2 Normative references 3 Terms and definitions |
60 | 4 Designation of fan coil units 5 Symbols 6 Air flow rate test for ducted units 6.1 General conditions |
61 | 6.2 Test installation 6.2.1 Outlet measurement method 6.2.2 Inlet measurement method |
62 | 6.3 Pressure settings |
63 | 6.4 Standard rating conditions 6.5 Test procedure |
64 | 6.6 Data to be recorded |
65 | 7 Capacity rating tests 7.1 General conditions 7.2 Test room 7.3 Installation of the test object 7.4 Standard rating conditions 7.4.1 Air flow conditions |
66 | 7.4.2 Temperature conditions 7.4.3 Electrical conditions 7.5 Test method 7.5.1 General |
67 | 7.5.2 Cooling capacity |
68 | 7.5.3 Total heating capacity 7.5.4 Total electric power input 7.6 Measurements criteria 7.6.1 Air inlet dry bulb temperature |
69 | 7.6.2 Moisture content 7.6.3 Liquid temperature 7.6.4 Liquid pressure 7.6.5 Condensate flow rate 7.6.6 Steady-state conditions |
70 | 7.7 Uncertainties of measurement from indicated values |
71 | 7.8 Test duration 7.9 Data to be recorded 8 Operating tests 8.1 General |
72 | 8.2 Test conditions 8.3 Sweat test 8.4 Condensate disposal test |
73 | 9 Test report 9.1 General information 9.2 Additional information 9.3 Test results 10 Manufacturer’s data |
75 | Annex A (informative) Drawings of the different types of configurations of fan coil units |
78 | Annex B (informative) Air flow rate test for non-ducted units |
80 | Annex C (normative) Design of separation partition for testing of cassette type fan coil units |