BS EN 14037-5:2016

$142.49

Free hanging heating and cooling surfaces for water with a temperature below 120°C – Open or closed heated ceiling surfaces. Test method for thermal output

Published By Publication Date Number of Pages
BSI 2016 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard describes the test method and the test installation for determining the thermal output of ceiling mounted heating surfaces according to the specifications 3.1, 3.2. and 3.3.

This part applies to determine thermal output when chilled ceilings according to EN 14240 are also used for heating.

NOTE

Test results according to this part cannot be compared with results according EN 14037‑2 because great discrepancies are given at open ceilings, convective components and heating surfaces without upper insulation.

PDF Catalog

PDF Pages PDF Title
4 Contents Page
5 European foreword
6 Introduction
7 1 Scope
2 Normative references
3 Terms and definitions
8 4 Symbols and units
Table 1 — Symbols and units
9 5 Testing of thermal output
10 Figure 1 — Example of a test booth with arrangement of a closed heated ceiling and the temperature measuring points
11 6 Test methods
7 Carrying out the measurement
7.1 General
7.2 Test design
7.3 Connection of the test sample to the measuring circuit
7.4 Mass flow
12 7.5 Test temperature
7.6 Reference room temperature
7.7 Steady-state conditions
7.8 Heat output
7.9 Result of measurement – characteristic equation
13 7.10 Standard output
7.11 Interpolation of values of the thermal output
8 Upper insulation
9 Test report
9.1 General
9.2 Data
15 10 Examples for the determination of the active length of different ceiling mounted heating surfaces
Figure 2 — Example for modules
16 Figure 3 — Example for modules connected in series
Figure 4 — Example for closed ceiling mounted heating surfaces
Figure 5 — Section of a ceiling mounted heating surface with single modules in a ceiling grid
17 Figure 6 — Ceiling mounted heating surfaces with 16 modules and a total active area Aatot = 16 × (X x Y) (upper sketch) Aatot = 12 × (X x Y) (lower sketch)
18 Figure 7 — Examples for free hanging sails Ai = L x B = Aatot
19 Figure 8 — Examples for free hanging sails Ai = 2 (L x B) = Aatot
20 Annex A (informative) Specimen of the test report for heating capacity
23 Bibliography