BS EN 26:2023 – TC 2024
$280.87
Tracked Changes. Gas-fired instantaneous water heaters for the production of domestic hot water
Published By | Publication Date | Number of Pages |
BSI | 2024 | 410 |
This European Standard defines the specifications and test methods concerning the construction, safety, rational use of energy and fitness for purpose, and also the classification and marking of gas-fired instantaneous water heaters for sanitary uses, hereafter called āwater heatersā. This European Standard applies to water heaters: – of types AAS, B11, B11BS, B12, B12BS, B13, B13BS, B14, B22, B23, B32, B33, B44, B52, B53, C11, C12, C13, C21, C22, C23, C32, C33, C42, C43, C52, C53, C62, C63, C72, C73, C82and C83 according to CEN/TR 1749; – fitted with atmospheric burners; – equipped with atmospheric burners assisted by a fan for the supply of combustion air or evacuation of combustion products or fully premix burners; – using one or more combustible gases corresponding to the three gas families and at the pressures stated in accordance to EN 437; – of nominal heat input not exceeding 70 kW; – with an ignition burner or with direct ignition of the main burner. In this European Standard, the heat inputs are expressed in relation to the net calorific value (Hi). This European Standard does not contain all the requirements necessary for: – boiling water appliances; – appliances intended to be connected to a mechanical means of evacuating the combustion products; – appliances which fulfil a dual role of space heating and heating water for sanitary use; – appliances making use of the heat of condensation of the water contained in the combustion products; – water heaters of types B21, B31, B41, B42, B43 and B51. This European Standard only covers water heaters where the fan, if any, is an integral part of the appliance. This European Standard: – does not apply to appliances not intended to be connected to a flue when they are not fitted with an atmosphere sensing device; – takes account of the information given in Technical Report CEN/CR 1472:1994 with respect to marking. Type B appliances should be with a combustion products discharge safety device to comply with essential requirement 3.4.3 of the Gas Appliances Directive 2009/142/EC. In this European Standard, the appliance is identified as type B11BS. Appliances intended to be installed outdoors or in a room separate from inhabited rooms and provided with appropriate ventilation are not required to have this combustion products discharge safety device but, in this case, appropriate warnings on the packaging, and in the instructions should clearly define the limited authorized use for this type of appliance. In this European Standard, the appliance is identified as type B11. The main symbols used in this European Standard are summarized in Annex F.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30485200 |
239 | A-30404047 |
240 | undefined |
249 | 1 Scope 2 Normative references |
252 | 3 Terms and definitions |
268 | 4 Classification 5 Constructional requirements |
269 | 5.2.1.1 General |
270 | 5.2.1.2 Use of Zinc alloy 5.2.2.1 Metallic materials |
273 | 5.2.7.1 Gas connections 5.2.7.2 Connection to the water circuit |
274 | 5.2.8.1 Soundness of the gas circuit 5.2.8.2 Soundness of the combustion circuit |
275 | 5.2.9.1 All appliances 5.2.9.2 Type AAS appliances 5.2.9.3 Type B appliances |
276 | 5.2.9.4 Separate combustion products evacuation duct 5.2.9.5 Type C appliances |
277 | 5.2.9.6 Special requirements for certain components of water heaters with a fan |
279 | 5.2.12.1 General 5.2.12.2 Controls |
283 | 5.3.7.1 Ignition burner |
284 | 5.3.7.2 Manual ignition of the ignition burner 5.3.7.3 Automatic ignition device 5.3.8.1 General |
285 | 5.3.8.2 Thermoelectric device of a permanent ignition burner 5.3.8.3 Flame supervision device of an appliance with an intermittent safety ignition burner 5.3.8.4 Flame supervision devices for automatic burner control systems |
287 | 5.3.13.1 Protection against frost 5.3.13.2 Protection against the ingress of rain |
288 | 5.5.2.1 Requirements 5.5.2.2 Test conditions |
289 | 6 Operational requirements 6.1.6.1 General 6.1.6.2 Test room 6.1.6.3 Conditions of installation |
291 | 6.1.6.4 Water supply 6.1.6.5 Measurement uncertainties |
293 | 6.1.6.6 Adjustment of the appliance |
294 | 6.1.6.7 Testing conditions 6.1.6.8 Electrical supply 6.2.1.1 Requirement 6.2.1.2 Test |
295 | 6.2.2.1 General |
296 | 6.2.2.2 Soundness after reassembly 6.2.2.3 General requirements 6.2.2.4 Soundness of the air supply and combustion product circuit type C appliances |
298 | 6.2.2.5 Soundness of the combustion product circuit of Type B appliances |
301 | 6.2.3.1 Requirements 6.2.3.2 Tests 6.3.1.1 Heat input obtained |
302 | 6.3.1.2 Corrected heat input |
303 | 6.3.2.1 Appliances without a preset adjuster 6.3.2.2 Appliances with preset adjusters |
304 | 6.3.3.1 Requirement 6.3.3.2 Test |
306 | 6.7.1.1 Requirements 6.7.1.2 Test |
307 | 6.7.2.1 Requirements |
308 | 6.7.2.2 Tests 6.7.3.1 Requirements 6.7.3.2 Tests |
309 | 6.7.3.3 Resistance to draught for water heaters intended to be installed outside and/or in a partially protected place |
310 | 6.7.4.1 Requirements 6.7.4.2 Tests 6.7.5.1 Requirements 6.7.5.2 Tests |
311 | 6.7.6.1 Requirements 6.7.6.2 Tests 6.7.7.1 Requirements 6.7.7.2 Tests 6.7.8.1 Requirements 6.7.8.2 Tests 6.7.9.1 Requirements 6.7.9.2 Tests 6.7.10.1 Requirements |
312 | 6.7.10.2 Tests 6.7.11.1 Requirements 6.7.11.2 Tests 6.7.12.1 General 6.7.12.2 Supervision of the combustion air rate and the combustion products rate |
313 | 6.7.12.3 Gas/air ratio controls |
314 | 6.7.12.4 Endurance of the gas/air ration control 6.7.12.5 Adjustment of the gas/air ratio 6.7.12.6 Supplementary test for type B water heaters with draught diverter |
315 | 6.7.13.1 Requirements 6.7.13.2 Test 6.7.14.1 General 6.7.14.2 Verification of the protected nature of a combustion chamber |
316 | 6.7.14.3 Verification of normal ignition in a combustible air/gas mixture for types C12 and C13 water heaters 6.7.15.1 Requirements 6.7.15.2 Test 6.7.16.1 Requirement |
317 | 6.7.16.2 Test 6.8.2.1 Rotary knob 6.8.2.2 Push-button 6.8.3.1 Sealing force |
318 | 6.8.3.2 Opening and closing function 6.8.3.3 Closing time 6.8.3.4 Endurance |
319 | 6.8.4.1 Automatic ignition devices 6.8.4.2 Heat input of ignition burners |
320 | 6.8.5.1 Appliances with a thermoelectric device 6.8.5.2 Appliances with an intermittent safety ignition burner 6.8.5.3 Appliances with automatic burner control systems |
322 | 6.8.6.1 Requirement |
323 | 6.8.6.2 Test 6.8.7.1 Requirement 6.8.7.2 Test 6.8.8.1 Requirement |
324 | 6.8.8.2 Test 6.8.9.1 Requirements 6.8.9.2 Tests 6.8.10.1 Sensitivity of the device to lack of ventilation in the room |
325 | 6.8.10.2 Sensitivity of the device to fouling of the heating body |
326 | 6.8.10.3 Operating defect of the device 6.8.11.1 General 6.8.11.2 Test conditions |
327 | 6.8.11.3 Nuisance shutdown 6.8.11.4 Shutdown times |
329 | 6.9.2.1 General |
330 | 6.9.2.2 Test in still air |
331 | 6.9.2.3 Water heaters using gas/air ratio controls 6.9.2.4 Supplementary tests |
333 | 6.9.3.1 General |
334 | 6.9.3.2 Weighting |
335 | 6.9.3.3 Calculation of emissions of NOX in mg/kWh based on GCV |
336 | 6.13.1.1 Requirements |
337 | 6.13.1.2 Test conditions 6.13.2.1 Requirement 6.13.2.2 Test conditions |
338 | 7 Rational use of energy |
340 | 8 Fitness for purpose 8.2.1.1 Requirements 8.2.1.2 Tests 8.2.2.1 Requirements 8.2.2.2 Tests 8.2.3.1 Nominal working combustion products temperature 8.2.3.2 Overheat combustion products temperature |
341 | 8.2.4.1 General 8.2.4.2 Compressive strength |
342 | 8.2.4.3 Lateral strength |
343 | 8.3.2.1 Characterization 8.3.2.2 Long-term resistance to thermal load |
345 | 8.3.2.3 Long-term resistance to condensate exposure |
346 | 8.3.2.4 Resistance to condensing/non-condensing cycling |
347 | 8.3.2.5 Resistance to ultraviolet radiation (UV) |
348 | 8.3.2.6 Geometrical stability 8.3.2.7 Reaction to fire 8.4.1.1 Requirements 8.4.1.2 Test conditions |
349 | 8.4.2.1 Requirements 8.4.2.2 Test conditions 8.4.3.1 Requirements |
350 | 8.4.3.2 Test conditions 8.4.4.1 Requirements 8.4.4.2 Test conditions |
351 | 8.4.5.1 Requirements 8.4.5.2 Test conditions 8.4.6.1 Requirements 8.4.6.2 Test conditions 8.4.7.1 Requirements 8.4.7.2 Test conditions |
352 | 8.4.8.1 Durability – Requirements 8.4.8.2 Strength 8.5.1.1 Requirement 8.5.1.2 Test 8.5.2.1 Requirements 8.5.2.2 Tests 8.5.3.1 Requirement 8.5.3.2 Test |
353 | 8.5.4.1 Requirement 8.5.4.2 Test 8.5.5.1 Normal and high water pressure appliances 8.5.5.2 Low water pressure appliances |
354 | 8.5.6.1 Fixed output or adjustable output appliances |
355 | 8.5.6.2 Appliances with automatic output variation |
358 | 8.5.7.1 Requirement 8.5.7.2 Test |
360 | 9 Marking and instructions |
361 | 9.1.3.1 General 9.1.3.2 Composition of packaging |
362 | 9.1.4.1 Presence of warning notices on water heater and packaging 9.1.4.2 Content of warning notices on water heater and packaging |
363 | 9.2.1.1 General |
365 | 9.2.1.2 For installation and adjustment of the gas circuit 9.2.1.3 For installation of the domestic hot water 9.2.1.4 For installation of the combustion circuit |
369 | 9.2.2.1 Presence of instructions for use and servicing 9.2.2.2 Content of instructions for use and servicing |
370 | 9.2.2.3 For type AAS appliances 9.2.2.4 For type B11BS, B12BS, B13BS appliances 9.2.2.5 For type C appliances |
371 | 9.2.3.1 Conversion instructions for the installer 9.2.3.2 Modification of warnings after conversion |
372 | 10 Nitrogen oxides emissions 11 Sound power level (LWA) |
373 | 12 Figures referenced in this standard |
385 | Annex A (informative)National situations A.1 General A.2 Gas connections in common use in the various countries |
388 | A.3 Flue pipe diameters in force in the various countries |
389 | Annex B (normative)Test apparatus for type C1, C3, B4 and B5 water heaters (see 6.7.3.2) |
393 | Annex C (normative)Test apparatus for type C21 appliances (see 6.7.4.2) |
394 | Annex D (normative)Description of the sealed room for the tests of type AAS appliances (see 6.8.10.1.2.1) D.1 Configuration of the sealed room D.2 Soundness of the room D.3 Effectiveness of mixing D.4 Equipment of the room |
395 | Annex E (informative)Soundness of the gas circuit test – Volumetric method(6.2.1) E.1 Equipment E.2 Test method |
396 | Annex F (informative)Principal symbols and abbreviations used |
398 | Annex G (informative)Guidelines for extension to other appliances categories |
399 | Annex H (normative)Lists of materials currently used for the construction of the gas water heaters H.1 General H.2 Special types of steel H.3 Copper and copper alloys |
400 | H.4 Plastic materials |
401 | Annex I (normative)Test methods to determine the effects of to long-term thermal load, long-term condensate exposure, condensing/ non-condensing cycling and resistance to UV radiation |
402 | Annex J (informative)NOx conversion calculation |
404 | Annex K (normative)Parts in copper or copper alloys |
405 | Annex L (informative)Compilation of the test conditions for the various gas families |
407 | Annex M (informative)Alternative Method for the determination of the nominal heat input or the maximum and minimum heat input (according to 6.3.1) for appliances using a pneumatic gas/air ratio control system |