BS EN 50121-2:2015

$142.49

Railway applications. Electromagnetic compatibility – Emission of the whole railway system to the outside world

Published By Publication Date Number of Pages
BSI 2015 32
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard is intended to define the electromagnetic environment of the whole railway system including urban mass transit and light rail system. It describes the measurement method to verify the emissions, and gives the cartography values of the fields most frequently encountered.

This European standard specifies the emission limits of the whole railway system to the outside world.

The emission parameters refer to the particular measuring points defined in Clause 5. These emissions should be assumed to exist at all points in the vertical planes which are 10 m from the centre lines of the outer electrified railway tracks, or 10 m from the fence of the substations.

Also, the zones above and below the railway system may be affected by electromagnetic emissions and particular cases shall be considered individually.

These specific provisions are to be used in conjunction with the general provisions in EN 50121‑1:2015 .

For existing railway lines, it is assumed that compliance with the emission requirements of EN 50121‑3‑1 , EN 50121‑3‑2 , EN 50121‑4 and EN 50121‑5 will ensure the compliance with the emission values given in this part.

For newly build railway systems it is best practice to provide compliance to the emission limits given in this part of the standard (to be defined in the EMC plan according to EN 50121‑1 ).

PDF Catalog

PDF Pages PDF Title
6 Foreword
8 1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
9 3.2 Abbreviations
4 Emission limits
4.1 Emission from the open railway system during train operation
4.2 Radio frequency emission from railway substations
10 5 Method of measurement of emission from moving rolling stock and substations
5.1 General and specific measurement parameters
5.1.1 General measurement parameters
5.1.1.1 Frequency bands
5.1.1.2 Measurement uncertainty
5.1.1.3 Types of antennas
11 5.1.1.4 Measurement distance and height
Table 1 – Conversion factor n
12 5.1.1.5 Values of measurement
5.1.1.6 Antenna position and orientation
5.1.1.7 Ambient noise
5.1.2 Measurement parameter for moving trains
13 5.1.3 Measurement parameter for railway substations
5.2 Acquisition methods
5.2.1 General
14 Table 2 – scan rate
5.2.2 Fixed frequency method
5.2.3 Frequency sweeping method
5.3 Transients
15 5.4 Measuring conditions
5.4.1 Weather conditions
5.4.2 Railway system operating modes
5.4.3 Multiple sources from remote trains
5.5 Test report
16 Figure 1 — Emission limits in frequency range 150 kHz to 1 GHz
17 Figure 2 — Emission limit for substations
18 Figure 3 – Position of antenna for measurement of horizontal component of magnetic field in the 150 kHz to 30 MHz frequency band
19 Figure 4 – Position (vertical polarization) of antenna for measurement of electric field in the 30 MHz to 300 MHz frequency band
20 Figure 5 – Position (vertical polarization) of antenna for measurement of electric field in the 300 MHz to 1 GHz frequency band
21 Annex A (informative) Background to the method of measurement
A.1 Introduction
A.2 Requirement for a special method of measurement
A.3 Justification for a special method of measurement
22 A.4 Frequency range
A.5 Antenna positions
A.6 Conversion of results if not measured at 10 m
A.7 Measuring scales
23 A.8 Repeatability of results
A.9 Railway system conditions
A.9.1 Weather
A.9.2 Speed, traction power
A.9.3 Multiple sources from remote trains
24 A.10 Number of traction vehicles per train
25 Annex B (informative) Cartography – Electric and Magnetic fields at traction frequencies
Table B.1 – Typical maximum electric and magnetic field values at fundamental frequency of different electrification systems
27 Annex C (informative) Emission values for lower frequency range
Figure C.1 – Emission values for the open railway system route
28 Figure C.2 – Emission values for railway substations
29 Annex ZZ (informative) Coverage of Essential Requirements of EU Directives
30 Bibliography
BS EN 50121-2:2015
$142.49