Shopping Cart

No products in the cart.

BS EN 50341-2-7:2015

$142.49

Overhead electrical lines exceeding AC 1 kV – National Normative Aspects (NNA) for FINLAND (based on EN 50341-1:2012)

Published By Publication Date Number of Pages
BSI 2015 32
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 General

1.2 Field of application

PDF Catalog

PDF Pages PDF Title
5 Foreword
7 1 Scope
1.1 General
1.2 Field of application
2 Normative references, definitions and symbols
2.1 Normative references
8 3 Basis of design
3.2 Requirements of overhead lines
3.2.2 Reliability requirements
3.2.5 Strength coordination
9 4 Actions on lines
4.3 Wind loads
4.3.1 Field of application and basic wind velocity
4.3.2 Mean wind velocity
10 4.3.3 Mean wind pressure
4.4 Wind forces on overhead line components
4.4.1 Wind forces on conductors
4.4.1.1 General
4.4.1.2 Structural factor
4.4.1.3 Drag factor
4.4.2 Wind forces on insulator sets
11 4.4.3 Wind forces on lattice towers
4.4.3.1 General
4.4.3.2 Method 1
4.4.4 Wind forces on poles
4.5 Ice loads
4.5.1 General
4.6 Combined wind and ice loads
4.6.2 Drag factors and ice densities
4.7 Temperature effects
12 4.8 Security loads
4.9 Safety loads
4.9.1 Construction and maintenance loads
13 4.12 Load cases
4.12.1 General
4.12.2 Standard load cases
15 4.13 Partial factors for actions
16 5 Electrical requirements
5.5 Minimum air clearance distances to avoid flashover
5.5.1 General
5.6 Load cases for calculation of clearances
5.6.1 Load conditions
17 5.6.2 Maximum conductor temperature
5.6.3 Ice loads for determination of electric clearances
5.8 Internal clearances within the span and at the top of support
5.9 External clearances
5.9.1 General
5.9.2 External clearances to ground in areas remote from buildings, roads etc.
18 5.9.3 External clearances to residential and other buildings
5.9.4 External clearances to crossing traffic routes
19 5.9.6 External clearances to other power lines or telecommunication lines
21 6 Earthing systems
6.1 Introduction
6.1.4 Transferred potentials
6.4 Dimensioning with regard to human safety
6.4.3 Design of earthing systems with regard to permissible touch voltage
7 Supports
7.3 Lattice steel towers
7.3.1 General
7.3.6 Ultimate limit states
7.3.6.1 General
22 7.5 Wood poles
7.5.3 Materials
7.5.5 Ultimate limit states
7.5.5.1 Basis
7.5.5.2 Calculation of internal forces and moments
7.5.5.3 Resistance of wood elements
7.5.5.4 Decay conditions
23 7.7 Guyed structures
7.7.4 Ultimate limit states
7.7.4.1 Basis
7.7.4.3 Second order analysis
7.7.6 Design details for guys
24 7.10 Maintenance facilities
7.10.3 Safety requirements
8 Foundations
8.1 Introduction
25 8.2 Basis of geotechnical design
8.2.1 General
8.2.2 Geotechnical design by calculation
26 8.2.3 Design by prescriptive measures
27 9 Conductors and earth wires
9.1 Introduction
28 9.6 General requirements
9.6.2 Partial factor for conductors
10 Insulators
10.2 Standard electrical requirements
10.11 Type test requirements
29 11 Hardware
11.6 Mechanical requirements
11.8 Material selection and specification
12 Quality assurance, checks and taking over
BS EN 50341-2-7:2015
$142.49