BS EN 50549-1:2019+A1:2023
$215.11
Requirements for generating plants to be connected in parallel with distribution networks – Connection to a LV distribution network. Generating plants up to and including Type B
Published By | Publication Date | Number of Pages |
BSI | 2023 | 74 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
10 | 1 Scope |
11 | 2 Normative references 3 Terms and definitions 3.1 General |
13 | 3.2 Plant, module and unit |
16 | 3.3 Power |
17 | 3.4 Voltage |
18 | 3.5 Circuit theory |
20 | 3.6 Protection |
24 | 3.7 Control |
25 | 4 Requirements on generating plants 4.1 General |
26 | 4.2 Connection scheme 4.3 Choice of switchgear 4.3.1 General 4.3.2 Interface switch |
27 | 4.4 Normal operating range 4.4.1 General 4.4.2 Operating frequency range |
28 | 4.4.3 Minimal requirement for active power delivery at underfrequency |
29 | 4.4.4 Continuous operating voltage range 4.5 Immunity to disturbances 4.5.1 General 4.5.2 Rate of change of frequency (ROCOF) immunity |
30 | 4.5.3 Under-voltage ride through (UVRT) 4.5.3.1 General 4.5.3.2 Generating plant with non-synchronous generating technology |
31 | 4.5.3.3 Generating plant with synchronous generating technology 4.5.4 Over-voltage ride through (OVRT) |
32 | 4.6 Active response to frequency deviation 4.6.1 Power response to overfrequency |
35 | 4.6.2 Power response to underfrequency |
38 | 4.7 Power response to voltage changes 4.7.1 General 4.7.2 Voltage support by reactive power 4.7.2.1 General 4.7.2.2 Capabilities |
40 | 4.7.2.3 Control modes |
43 | 4.7.3 Voltage related active power reduction 4.7.4 Short circuit current requirements on generating plants 4.7.4.1 General 4.7.4.2 Generating plant with non-synchronous generating technology |
44 | 4.7.4.3 Generating plant with synchronous generating technology – Synchronous generator based units 4.8 EMC and power quality |
45 | 4.9 Interface protection 4.9.1 General |
46 | 4.9.2 Void |
47 | 4.9.3 Requirements on voltage and frequency protection 4.9.3.1 General 4.9.3.2 Undervoltage protection [27] |
48 | 4.9.3.3 Overvoltage protection [59] 4.9.3.4 Overvoltage 10 min mean protection 4.9.3.5 Underfrequency protection [81 < ] |
49 | 4.9.3.6 Overfrequency protection [81 > ] 4.9.4 Means to detect island situation 4.9.4.1 General 4.9.4.2 Active methods tested with a resonant circuit 4.9.4.3 Switch to narrow frequency band (see Annex E and Annex F) |
50 | 4.9.5 Digital input to the interface protection 4.10 Connection and starting to generate electrical power 4.10.1 General 4.10.2 Automatic reconnection after tripping 4.10.3 Starting to generate electrical power |
51 | 4.10.4 Synchronization 4.11 Ceasing and reduction of active power on set point 4.11.1 Ceasing active power 4.11.2 Reduction of active power on set point 4.12 Remote information exchange |
52 | 4.13 Requirements regarding single fault tolerance of interface protection system and interface switch |
53 | Annex A (informative) Interconnection guidance A.1 General A.2 Network integration |
54 | A.3 Clusters of single-phase generating units |
55 | Annex B (informative)Void |
56 | Annex C (informative) Parameter Table |
61 | Annex D (informative)List of national requirements applicable for generating plants |
63 | Annex E (informative)Loss of Mains and overall power system security |
64 | Annex F (informative)Examples of protection strategies F.1 Introduction F.1.1 General F.1.2 Generalities F.1.3 Detection of unwanted islands |
65 | F.1.4 Problems with uncontrolled islanding in MV networks F.1.4.1 Safety F.1.4.2 Grid parameters F.1.4.3 Reclosing operations F.1.4.4 Protection of islands against overcurrents F.1.4.5 Protection against phase to earth faults |
66 | F.2 Example strategy 1 |
69 | F.3 Example strategy 2 |
71 | Annex G (normative)Abbreviations |
72 | Annex H (informative)Relationship between this European standard and the COMMISSION REGULATION (EU) 2016/631 |