Shopping Cart

No products in the cart.

BS EN IEC 61158-5-24:2023

$215.11

Industrial communication networks. Fieldbus specifications – Application layer service definition. Type 24 elements

Published By Publication Date Number of Pages
BSI 2023 108
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
6 Blank Page
7 CONTENTS
10 FOREWORD
12 INTRODUCTION
13 1 Scope
1.1 General
14 1.2 Specifications
1.3 Conformance
2 Normative references
15 3 Terms, definitions, symbols, abbreviated terms and conventions
3.1 Referenced terms and definitions
3.1.1 ISO/IEC 74981 terms
3.1.2 ISO/IEC 9545 terms
3.1.3 ISO/IEC 88241 terms
16 3.1.4 Terms and definitions from ISO/IEC 10731
3.2 Additional terms and definitions
21 3.3 Abbreviations and symbols
22 3.4 Conventions
3.4.1 Overview
23 3.4.2 Conventions for class definitions
24 3.4.3 Conventions for service definitions
25 4 Concepts
5 Data type ASE
6 Communication model specifications
6.1 Type specific concepts
26 6.2 Overview
27 Tables
Table 1 – AP type definition
28 6.3 FSM ASE
6.3.1 Concepts
Figures
Figure 1 – FAL ASE model of Type 24
29 6.3.2 FieldbusSystemManager class specifications
Table 2 – Support list of service for each class of FSM ASE
31 Table 3 – FSM-Reset
Table 4 – FSM-GetStatus
32 Table 5 – FSM-SetContext
33 Table 6 – FSM-GetContext
34 6.4 FAL ASEs
6.4.1 Field Device Control ASE
Table 7 – FSM-Start
Table 8 – Support list of service for each class of FDC ASE
38 Table 9 – FDC-Reset for master class
Table 10 – FDC-Open for master class
39 Table 11 – FDC-Enable for master class
40 Table 12 – FDC-Connect for master class
41 Table 13 – FDC-SyncSet for master class
42 Table 14 – FDC-Disconnect for master class
43 Table 15 – FDC-ResumeCycle for master class
Table 16 – FDC-ComCycle for master class
44 Table 17 – FDC-Command for master class
45 Table 18 – FDC-DataExchange for master class
49 Table 19 – FDC-Reset for slave class
Table 20 – FDC-Open for slave class
50 Table 21 – FDC-Enable for slave class
51 Table 22 – FDC-Connect for slave class
52 Table 23 – FDC-SyncSet for slave class
54 Table 24 – FDC-Disconnect for slave class
55 Table 25 – FDC-ResumeCycle for slave class
Table 26 – FDC-ComCycle for slave class
56 Table 27 – FDC-Command for slave class
57 Table 28 – FDC-Command for slave class
59 Table 29 – FDC-Reset for monitor class
60 Table 30 – FDC-Open for monitor class
Table 31 – FDC-Enable for monitor class
61 Table 32 – FDC-GetCMD for monitor class
62 Table 33 – FDC-GetRSP for monitor class
63 6.4.2 Message ASE
Table 34 – Support list of service for each class of Message ASE
65 Table 35 – MSG-Reset for requester class
66 Table 36 – MSG-Open for requester class
Table 37 – MSG-Enable for requester class
67 Table 38 – MSG-UserMessage for requester class
69 Table 39 – MSG-OnewayMessage for requester class
70 Table 40 – MSG-AbortTransaction for requester class
72 Table 41 – MSG-Reset for responder class
73 Table 42 – MSG-Open for responder class
Table 43 – MSG-Enable for responder class
74 Table 44 – MSG-UserMessage for responder class
75 Table 45 – MSG-OnewayMessage for responder class
76 6.4.3 Event Management ASE
Table 46 – MSG-AbortTransaction for responder class
77 Table 47 – Support list of service for each class of Event Management ASE
78 Table 48 – EVM-Reset
Table 49 – EVM-Enable
79 Table 50 – EVM-SyncEvent
Table 51 – EVM-ReadNetClock
80 6.5 FAL ARs
6.5.1 AR model
Table 52 – Support list of service for each class of AR ASE
82 Figure 2 – AR model for field device control service
Figure 3 – AR model for message service
83 6.5.2 FDC AREP
Figure 4 – MSG ARs between each APs
85 Table 53 – AR-Reset for FDC Master AR class
86 Table 54 – AR-Open for FDC Master AR class
Table 55 – AR-Enable for FDC Master AR class
87 Table 56 – AR-CycleEvent for FDC Master AR class
Table 57 – AR-StartComCycle for FDC Master AR class
88 Table 58 – AR-ResetCycle for FDC Master AR class
89 Table 59 – AR-SendCommand for FDC Master AR class
92 Table 60 – AR-Reset for FDC Slave AR class
Table 61 – AR-Open for FDC Slave AR class
93 Table 62 – AR-Enable for FDC Slave AR class
Table 63 – AR-CycleEvent for FDC Slave AR class
94 Table 64 – AR-StartComCycle for FDC Slave AR class
Table 65 – AR-ResetCycle for FDC Slave AR class
95 Table 66 – AR-SendCommand for FDC Slave AR class
97 Table 67 – AR-Reset for FDC Monitor AR class
98 Table 68 – AR-Open for FDC Monitor AR class
Table 69 – AR-Enable for FDC Monitor AR class
99 Table 70 – AR-GetCMD for FDC Monitor AR class
100 Table 71 – AR-GetCMD for FDC Monitor AR class
101 6.5.3 MSG AREP
102 Table 72 – AR-Reset for Message AR class
103 Table 73 – AR-Open for Message AR class
Table 74 – AR-Enable for Message AR class
104 Table 75 – AR-SendMessage for Message AR class
105 Table 76 – AR-ReceiveMessage for Message AR class
106 Table 77 – AR-AbortMessage for Message AR class
107 Bibliography
BS EN IEC 61158-5-24:2023
$215.11