BS EN ISO 12569:2012:2013 Edition
$198.66
Thermal performance of buildings and materials. Determination of specific airflow rate in buildings. Tracer gas dilution method
Published By | Publication Date | Number of Pages |
BSI | 2013 | 60 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | Introduction |
8 | 1 Scope 2 Terms and definitions |
9 | 3 Measurement method and its selection 3.1 General |
10 | Table tab_1 |
11 | 3.2 Concentration decay method |
14 | 3.3 Continuous dose method |
16 | 3.4 Constant concentration method |
17 | Table tab_2 3.5 Type of tracer gas |
18 | Table tab_3 3.6 Measurement apparatus |
20 | 4 Procedure 4.1 Building preparations 4.2 Ancillary measurements 4.3 Concentration decay method |
22 | Table tab_j Figure fig_1 |
25 | Table tab_m Figure fig_2 |
26 | Table tab_n Figure fig_3 |
27 | Table tab_o Figure fig_4 4.4 Continuous dose methods |
29 | Table tab_q Figure fig_5 |
31 | Table tab_t Figure fig_6 |
32 | Table tab_v Figure fig_7 4.5 Constant concentration method |
34 | Table tab_x Figure fig_8 5 Accuracy |
35 | 5.1 Tracer gas dose procedure and room concentration distribution 5.2 Tracer gas sampling and storage method 5.3 Tracer gas concentration measuring instruments |
36 | 5.4 Changes in outside wind and outside air temperature and schedule of air conditioning system 6 Test report 6.1 General 6.2 All details necessary to identify the simulation tested 6.3 Details of heating and ventilation systems |
37 | 6.4 Test conditions and apparatus 6.5 Collected data and results 6.6 Date of the test |
38 | Annex A (normative) Confidence intervals |
39 | Table tab_A.1 |
41 | Annex B (normative) Method to estimate ventilation rate QV and effective mixed zone volume Vemz simultaneously [3,4] |
44 | Table tab_ac Figure fig_B.1 |
45 | Table tab_ad Figure fig_B.2 |
46 | Annex C (informative) Considerations when measuring the ventilation rate of large spaces |
47 | Annex D (informative) Effects of internal and external temperature difference, temperature change, and outside air concentration change during the measurement period |
51 | Annex E (informative) Estimation error minimizing method in 2-point and multi-point decay method |
54 | Table tab_ai Figure fig_E.1 |
56 | Annex F (informative) Propagation of error analysis Propagation of error analysis |
58 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Reference ref_7 Reference ref_8 Bibliography Bibliography |