BS ISO 12926:2012:2013 Edition
$102.76
Aluminium fluoride for industrial use. Determination of trace elements. Wavelength dispersive X-ray fluorescence spectrometric method using pressed powder tablets
Published By | Publication Date | Number of Pages |
BSI | 2013 | 22 |
This International Standard describes an X-ray fluorescence spectrometric (XRF) method for the determination of aluminium fluoride (AlF3) from the content of fluorine and the content of trace elements in the test specimen. The method does not determine the oxygen content. The calibration reference materials are not specified in this method.
The method is applicable to industrial-grade aluminium fluoride where the concentration range for aluminium fluoride and each trace element is within the concentration range given in Table 1. The validity and precision of test results for concentrations outside these ranges has not been determined (see Note).
Table 1
Concentration range for aluminium fluoride (from fluorine) and trace elements
NOTE The determination of fluorine has an uncertainty due to mineralogical variation among origins of aluminium fluoride. Batches from different origins with the same fluorine contents can give different intensities when determined by this method and pressed tablet preparation does not eliminate this problem. An AlF3 sample of unusual mineralogical origin should be tested with an absolute method to verify that, when using this test method, the fluorine concentration range reported is valid.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
7 | Introduction |
9 | Section sec_1 Table tab_1 Section sec_2 Section sec_3 1 Scope 2 Normative references 3 Principle |
10 | Section sec_4 Section sec_4.1 Section sec_4.2 Section sec_4.3 Section sec_4.4 Section sec_4.5 Section sec_4.6 Section sec_5 Section sec_5.1 4 Reagents and materials 5 Apparatus |
11 | Section sec_5.2 Section sec_5.3 Section sec_5.4 Section sec_5.5 Section sec_5.6 Section sec_5.7 Section sec_6 Section sec_6.1 Section sec_6.2 Section sec_6.2.1 Section sec_6.2.2 Section sec_6.2.3 Table tab_2 Section sec_6.2.4 6 Test procedure 6.1 Test specimen preparation 6.2 Addition of binder method |
12 | Section sec_6.3 Section sec_6.3.1 Section sec_6.3.2 Section sec_6.3.3 Section sec_6.3.4 Section sec_6.3.5 Section sec_6.4 Section sec_6.4.1 6.3 Backing method 6.4 X-ray fluorescence spectrometer application |
13 | Table tab_3 Section sec_6.4.2 |
14 | Section sec_6.4.3 Section sec_6.5 Section sec_6.6 Section sec_7 Section sec_7.1 6.5 Monitor sample for correction of instrumental drift 6.6 Analysis, calculation and expression of results 7 Precision 7.1 General |
15 | Table tab_4 Section sec_7.2 Section sec_7.2.1 Section sec_7.2.2 Section sec_7.2.3 Section sec_7.2.4 Section sec_7.2.5 Section sec_7.3 Section sec_7.3.1 Section sec_7.3.2 7.2 How to use Table 4 using sodium (Na) as an example 7.3 How to use Table 4 using sulfur (S) as an example |
16 | Section sec_7.3.3 Section sec_8 8 Test report |
17 | Annex sec_A Table tab_A.1 Annex A (informative) Conversion table |
18 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Bibliography |