Shopping Cart

No products in the cart.

BSI 15/30325873 DC:2015 Edition

$13.70

BS EN 14782. Self-supporting metal sheet for roofing, external cladding and internal lining. Product specification and requirements

Published By Publication Date Number of Pages
BSI 2015 45
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
4 Contents Page
6 Foreword
7 1 Scope
Figure 1 — Illustration of a cassette
2 Normative references
8 3 Terms and definitions
9 4 Requirements
4.1 Materials
4.2 Nominal thickness
Table 1 — Minimum nominal values of thickness of self-supporting metal sheet excluding any organic, inorganic or multi-layer coating
4.3 Mechanical resistance
4.3.1 General
10 4.3.2 Resistance of roofing products to concentrated forces
4.4 Water permeability
4.5 Vapour and air permeability
4.6 Dimensional change
4.7 Dimensional tolerances
11 4.8 Durability
4.9 External fire performance
4.10 Reaction to fire
4.11 Release of regulated dangerous substances
5 Testing, assessment and sampling methods
5.1 External fire performance for roof covering products
5.1.1 Products deemed to satisfy the requirements for external fire performance
5.1.2 Products classified without the need for further testing (CWFT option)
12 5.1.3 Other products
5.2 Reaction to fire
5.2.1 Products satisfying the requirements for reaction to fire Class A1 without the need for testing
5.2.2 Products classified without the need for further testing (CWFT option)
5.2.3 Other products
6 Assessment and verification of constancy of performance – AVCP
6.1 General
6.2 Type testing
6.2.1 General
14 Table 2 — Test methods, number of specimens and conformity criteria for type testing of base material
15 Table 3 — Test methods, number of specimens and conformity criteria for type testing of the finished product
6.2.2 Sampling for product type determination
6.3 Factory production control (FPC)
6.3.1 General
16 Table 4 — Test methods, number of specimens and conformity criteria for FPC of base material
6.3.2 Requirements
17 Table 5 — Test methods, number of specimens and conformity criteria for FPC of the finished product
7 Designation
18 8 Product marking
19 Annex A (normative) Multilayer coated steel sheet
A.1 General
A.2 Substrate material
A.3 Specific requirements
A.3.1 Minimum nominal values of thickness
A.3.2 Bituminous coating specification
A.3.3 Durability
20 A.4 Freedom from defects
21 Annex B (normative) Determination of resistance to concentrated forces
B.1 Principle
B.2 Test spans
22 Figure B.1 — Test layout and measurement of the span
B.3 Test sheets
B.4 Test procedure
23 Figure B.2 — Application of the concentrated force
B.5 Number of tests and analysis of results
24 B.6 Acceptance criteria
B.7 Test report
26 Annex C (normative) Mounting and fixing conditions of the test specimen for reaction to fire testing
C.1 General
C.2 Mounting and fixing conditions
C.2.1 General
C.2.2 General configuration
27 Figure C.1 — Illustration of the test arrangement for reaction to fire test according to EN 13823 (SBI) on metal sheet products – assembly and corner detail
28 C.2.3 Securing the overlap vertical joint
C.2.4 Standard assembly – Steel corner flashings
C.2.5 Alternative assembly – Corner flashings and seals
C.2.6 Test arrangement for reaction to fire test according to EN ISO 11925-2 (Ignitability test)
29 C.3 Direct and extended application of the fire test results according to EN 13823
C.3.1 General
C.3.2 Direct application: Systems with only one metal sheet (single skin system without insulation)
C.3.2.1 Case of steel
30 Table C.1 — Mounting and fixing conditions for coated steel sheet and associated direct application
C.3.2.2 Case of other metals
31 Table C.2 — Mounting and fixing conditions for other metal coated sheet and associated direct application
C.3.3 Direct application: Systems with two (profiled or flat) coated metal sheets (or one cassette plus one sheet) with an insulation between the two sheets (double skin system)
C.3.3.1 General
C.3.3.2 Systems with two coated steel sheets (or one coated steel cassette plus one coated steel sheet) and with an insulation of mineral wool or glass wool of thickness 80 mm maximum between the two sheets
32 C.3.3.3 Systems with two coated steel sheets (or one coated steel cassette plus one coated steel sheet) and with an insulation in mineral wool or glass wool of thickness less than or equal to 160 mm between the two sheets
C.3.3.3.1 Case where the coating is plastisol 200 µm (PCS ≤ 7 MJ/m2, mass ≤ 300 g/m2)
Table C.3 — Classification of a steel sheet coated with plastisol 200 µm in a double skin system
33 Table C.4 — Mounting and fixing conditions, and associated direct application, for plastisol 200 µm (mass ≤ 300 g/m2 and PCS ≤ 7 MJ/m2) in a double skin system
C.3.3.3.2 Case where the organic coating has a thickness less than or equal to 25 µm (mass ≤ 70 g/m2 and PCS ≤ 1 MJ/m2)
Table C.5 — Classification of polyester coating 25 µm (maximum mass ≤ 70 g/m2 and PCS ≤ 1 MJ/m2) sheet in a double layer system
34 Table C.6 — Mounting and fixing conditions, and associated direct application, of Polyester 25 µm (maximum mass 70 g/m2 and PCS ≤ 1 MJ/m2) in a double layer system
C.3.4 Extended application: Other insulated systems – General methodology
C.3.4.1 Principle
C.3.4.2 Principle of the insulated test specimens
35 C.3.4.3 Determination of the extended application for the actual system
C.3.4.4 Example values of Rcrit for some identified coatings on steel sheets
Table C.7 — Example values of Rcrit
36 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation
ZA.1 Scope and relevant characteristics
Table ZA.1.1 — Relevant clauses for factory made self-supporting metal sheets and tiles (for non-structural applications) and intended use: internal and external wall and ceiling finishes
37 Table ZA.1.2 — Relevant clauses for factory made self-supporting metal sheets and tiles (for non-structural applications) and intended use:roof coverings
38 ZA.2 Procedure for AVCP of factory made self-supporting metal sheets and tiles (for non-structural applications)
ZA.2.1 Systems of AVCP
Table ZA.2 — Systems of AVCP
39 Table ZA.3.1 — Assignment of AVCP tasks for factory made self-supporting metal sheets and tiles (for non-structural applications)under system 1
40 Table ZA.3.2 — Assignment of AVCP tasks for factory made self-supporting metal sheets and tiles (for non-structural applications)under system 3
Table ZA.3.3 — Assignment of AVCP tasks for factory made self-supporting metal sheets and tiles (for non-structural applications) under system 4
ZA.2.2 Declaration of performance (DoP)
ZA.2.2.1 General
41 ZA.2.2.2 Content
42 ZA.2.2.3 Example of DoP
43 ZA.3 CE marking and labelling
44 Figure ZA.1 — Example of the information accompanying CE marking, for a product “deemed to satisfy” reaction to fire and requiring testing for external fire performance, and with no regulated substances, and therefore under system 4
45 Bibliography
BSI 15/30325873 DC
$13.70