BSI 19/30402920 DC:2019 Edition

$13.70

BS EN IEC 60364-5-53 AMD1. Low-Voltage electrical installations – Part 5-53. Selection and erection of electrical equipments. Isolation, switching and control Clause 531

Published By Publication Date Number of Pages
BSI 2019 19
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
5 531 Equipment for protection against electric shock
531.1 General
531.2 Devices for automatic disconnection of supply
531.2.1 General
531.2.2 Overcurrent protective devices
531.2.2.1 TN system
An overcurrent protective device shall be so selected that its operating characteristics meet the following requirement:
6 Uo is the nominal AC or DC line-to-earth voltage in volts (V).
531.2.2.2 TT system
531.2.2.3 IT system
7 531.2.3 Residual current protective devices
531.2.3.1 General conditions of installation
8 531.2.3.2 Unwanted tripping
531.2.3.3 Types of RCDs
531.2.3.3.1 Selection of type of RCD
531.2.3.3.2 Selection of the types of RCDs connected in series
531.2.3.4 Selection according to the accessibility to the installation
531.2.3.4.1
In AC installations where RCDs are accessible to ordinary persons (BA1), children (BA2) or handicapped persons (BA3) residual current protective devices shall comply with:
531.2.3.4.2
9 531.2.3.4.3
531.2.3.5 Selection of RCD according to the type of system earthing
531.2.3.5.1 TN systems
531.2.3.5.2 TT systems
10 531.2.3.5.3 IT systems
531.2.3.5.3.1 Disconnection at first fault condition
531.2.3.5.3.2 Disconnection at second fault condition
11 531.3 Equipment for protection by double or reinforced insulation
531.3.1 General
531.3.2
The following requirements apply as specified:
12 531.3.3
Where lids or doors in the insulating enclosure can be opened without the use of a tool or key, all conductive parts which are accessible if the lid or door is open shall be behind an insulating barrier (providing a degree of protection not less tha…
531.3.4
Conductive parts enclosed in the insulating enclosure shall not be connected to a protective conductor. However, provision may be made for connecting protective conductors which necessarily run through the enclosure in order to serve other items of e…
531.3.5
531.3.6
531.3.7 Installation
The installation of equipment mentioned in 412.2.1 of IEC 60364-4-41: 2017 (fixing, connection of conductors, etc.) shall be effected in such a way as not to impair the protection afforded in compliance with the equipment specification.
531.4 Equipment for protection by protective electrical separation
531.5 Equipment for protection by extra-low-voltage provided by SELV and PELV systems
531.5.1 Sources for SELV or PELV systems
 A safety isolating transformer in accordance with IEC 61558-2-6.
 A source of current providing a degree of safety equivalent to that of the safety isolating transformer specified before (e.g. motor generator with windings providing equivalent isolation).
 An electrochemical source (e.g. a battery) or another source independent of a higher voltage circuit (e.g. a diesel-driven generator).
 Certain electronic devices complying with appropriate standards where provisions have been taken in order to ensure that, even in the case of an internal fault, the voltage at the outgoing terminals cannot exceed the values specified in Clause 414.1…
13  Mobile sources supplied at low voltage, e.g. safety isolating transformers or motor generators, shall be selected or erected in accordance with the requirements for protection by the use of double or reinforced insulation (see Clause 412 IEC 60364-4…
531.5.2 Selection of plugs and socket-outlets
531.6 Devices for additional protection
531.7 Monitoring devices
14 Annex A (informative) Description of the different types of residual current devices (RCDs)
18 Annex B (informative) List of notes concerning certain countries
BSI 19/30402920 DC
$13.70