{"id":179306,"date":"2024-10-19T11:10:49","date_gmt":"2024-10-19T11:10:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d4327-2017\/"},"modified":"2024-10-25T03:27:47","modified_gmt":"2024-10-25T03:27:47","slug":"astm-d4327-2017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d4327-2017\/","title":{"rendered":"ASTM-D4327 2017"},"content":{"rendered":"

ASTM D4327-17<\/h3>\n

Active Standard: Standard Test Method for Anions in Water by Suppressed Ion Chromatography<\/h4>\n
\n

ASTM D4327<\/h4>\n

Scope<\/strong><\/p>\n

\n

1.1<\/span> This test method2<\/span><\/span>,<\/sup>3<\/span><\/span> covers the sequential determination of fluoride, chloride, nitrite, ortho<\/span>-phosphate, bromide, nitrate, and sulfate ions in water by suppressed ion chromatography.<\/p>\n

\n

Note 1:<\/span> Order of elution is dependent upon the column used; see Fig. 1<\/span>.<\/span><\/p>\n<\/p><\/div>\n

\n
<\/div>\n<\/p><\/div>\n
\n

1.3<\/span> It is the user’s responsibility to ensure the validity of this test method for other matrices.<\/p>\n<\/p><\/div>\n

\n

1.4<\/span> Concentrations as low as 0.01 mg\/L were determined depending upon the anions to be quantified, in single laboratory work. Utilizing a 50-\u03bcL sample volume loop and a sensitivity of 3000 \u03bcS\/cm full scale, the approximate detection limits shown in Table 1<\/span> can be achieved. Lower detection limits have been observed with newer instrumentation, column technology and eluents. The analyst must assure optimum instrument performance to maintain a stable baseline at more sensitive conductivity full-scale settings.<\/p>\n

\n
\n (A)<\/span> Data provided by U.S. EPA\/EMSL Laboratory, Cincinnati, OH.<\/span>\n <\/div>\n
\n (B)<\/span> Column: as specified in 7.1.4<\/span>. \u2007\u2007Detector: as specified in 7.1.6<\/span>. \u2007\u2007Eluent: as specified in 8.3<\/span>. \u2007\u2007Pump rate: 2.0 mL\/min. \u2007\u2007Sample loop: 50 \u03bcL.<\/span>\n <\/div>\n<\/p><\/div>\n<\/p><\/div>\n
\n

1.5<\/span> The upper limit of this test method is dependent upon total anion concentration and may be determined experimentally as described in Annex A1<\/span>. These limits may be extended by appropriate dilution or by use of a smaller injection volume.<\/p>\n<\/p><\/div>\n

\n

1.6<\/span> Using alternate separator column and eluents may permit additional anions such as acetate, formate, or citrate to be determined. This is not the subject of this test method.<\/p>\n<\/p><\/div>\n

\n

1.7<\/span> This test method update approves the use of electrolytically generated eluent, electrolytically regenerated eluent, electrolytic suppression (not autozeroing), and electrolytic trap columns also known as reagent-free ion chromatography. This approval is based on acceptance by the U.S. EPA as referenced in Appendix X2<\/span>.<\/p>\n<\/p><\/div>\n

\n

1.8<\/span> The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n<\/p><\/div>\n

\n

1.9<\/span> This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n<\/p><\/div>\n

\n

1.10<\/span> This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.<\/i><\/p>\n<\/p><\/div>\n

Keywords<\/strong><\/p>\n

anions; drinking water; ion chromatography; reagent water; wastewater;<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 71.040.40 (Chemical analysis)<\/p>\n

DOI:<\/strong> 10.1520\/D4327-17<\/p>\n<\/p><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"

D4327-17 Standard Test Method for Anions in Water by Suppressed Ion Chromatography<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2017<\/td>\n13<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":179309,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1000,2637],"product_tag":[],"class_list":{"0":"post-179306","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-040-40","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/179306","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/179309"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=179306"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=179306"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=179306"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}