{"id":226017,"date":"2024-10-19T14:41:16","date_gmt":"2024-10-19T14:41:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60432-32013\/"},"modified":"2024-10-25T08:35:32","modified_gmt":"2024-10-25T08:35:32","slug":"bs-en-60432-32013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60432-32013\/","title":{"rendered":"BS EN 60432-3:2013"},"content":{"rendered":"
IEC 60432-3:2012 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: – projection (including cinematograph and still projection), – photographic (including studio), – floodlighting, – special purpose, – general purpose, – stage lighting. This second edition of IEC 60432-3 cancels and replaces the first edition published in 2002, Amendment 1 (2005) and Amendment 2 (2008). The main changes with respect to the previous edition are as follows: – adapting the cold fill pressure requirements and tests for self-shielded lamps to the state of the technology, – introduction of requirements to fully cover photobiological safety according to IEC 62471.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 General 1.1 Scope 1.2 Normative references <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1.3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 2 Requirements 2.1 General <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 2.2 Marking 2.2.1 Lamp marking 2.2.2 Additional information and marking <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 2.3 Caps or bases 2.3.1 General 2.3.2 Creepage distances 2.3.3 Dimensions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 2.4 Photobiological safety 2.5 Gas pressure of low-pressure self-shielded extra low voltage lamps 2.6 Safety at end of life of self-shielded lamps with rated voltages from range B or C 2.7 Information for luminaire design <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3 Assessment 3.1 General 3.2 Whole production assessment by means of manufacturer\u2019s records <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Tables Table 1 \u2013 Grouping of test records \u2013 Sampling and acceptable quality levels (AQL) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Table 2 \u2013 Acceptance numbers AQL = 0,25 % Table 3 \u2013 Acceptance numbers AQL = 0,65 % <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Table 4 \u2013 Acceptance numbers AQL = 2,5 % <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 3.2.1 Assessment of manufacturer\u2019s records for particular tests 3.2.2 Sampling procedures for the whole production testing <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 3.3 Assessment of batches 3.3.1 Sampling for batch testing 3.3.2 Number of lamps in the batch sample 3.3.3 Sequence of the tests 3.3.4 Rejection conditions of batches Table 5 \u2013 Batch sample size and rejection number <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex A (normative) Symbols <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex B (normative) Method of testing the gas-pressure <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex C (informative) Information for luminaire design <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Table C.1 \u2013 Fuse values for general purpose ELV tungsten halogen lamps <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Table C.2 \u2013 Fuse values for photographic lamps Table C.3 \u2013 List of maximum bulb temperatures <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Table C.4 \u2013 Maximum base-pin temperatures <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Table C.5 \u2013 Maximum contact temperatures Table C.6 \u2013 Maximum reflector-rim temperatures <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex D (normative) Conditions of compliance for design tests <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex E (informative) Bulb wall temperature measurement <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex F (normative) Induced failure test <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Incandescent lamps. Safety specifications – Tungsten-halogen lamps (non-vehicle)<\/b><\/p>\n |