{"id":276238,"date":"2024-10-19T18:35:29","date_gmt":"2024-10-19T18:35:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-20794-62020\/"},"modified":"2024-10-25T15:01:42","modified_gmt":"2024-10-25T15:01:42","slug":"bs-iso-20794-62020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-20794-62020\/","title":{"rendered":"BS ISO 20794-6:2020"},"content":{"rendered":"
This document specifies the transport and network layer conformance test plan, which tests the transportation of diagnostic communication, node configuration data and network layer services using the service interface parameters reported by the lower OSI layers and submitted to the higher OSI layers.<\/p>\n
The transport layer and network layer conformance test plan contain the following descriptions:<\/p>\n
concept of operation conformance test plan;<\/p>\n<\/li>\n
transport layer protocol conformance test plan;<\/p>\n<\/li>\n
network layer services conformance test plan; and<\/p>\n<\/li>\n
error detection conformance test plan.<\/p>\n<\/li>\n<\/ul>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4 Symbols and abbreviated terms 4.1 Symbols <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.2 Abbreviated terms 5 Conventions 6 General test specification considerations 6.1 General <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6.2 Test conditions 6.3 IUT requirements 6.4 CTC definition <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.5 Test system set-up <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.6 Configuration of test system and IUT 6.6.1 General <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.6.2 IUT-specific set-up parameters 6.6.3 User_Specific configurations 6.6.4 T_FltMng1 configurations 6.6.5 T_FltMng2 configurations <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.6.6 N_ErrDet1 configurations 6.6.7 N_ErrDet2 configurations 6.6.8 W\/S configurations 6.7 SUT initialisation 6.7.1 General 6.7.2 Default initialisation 7 Transport layer conformance test plan 7.1 General <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.2 4.CTC_1.1 \u2013 Master node \u2013 T_PDU and T_PCI data handling \u2013 T_PCItype and T_PCI_DL 7.3 4.CTC_1.2 \u2013 Slave node \u2013 T_PDU and T_PCI data handling \u2013 T_PCItype and T_PCI_DL <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.4 4.CTC_1.3 \u2013 Master node \u2013 T_PDU and T_PCI data handling (T_PCItype and T_PCI_DLext) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.5 4.CTC_1.4 \u2013 Slave node \u2013 T_PDU and T_PCI data handling (T_PCItype and T_PCI_DLext) <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.6 4.CTC_1.5 \u2013 Master node \u2013 T_PDU and T_PCI data handling (T_PCItype and T_PCI_DLext with short data field) <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7.7 4.CTC_1.6 \u2013 Slave node \u2013 T_PDU and T_PCI data handling (T_PCItype and T_PCI_DLext with short data field) <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 7.8 4.CTC_2.1 \u2013 Master node \u2013 TL Error detection test (T_PCItype) <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.9 4.CTC_2.2 \u2013 Slave node \u2013 TL Error detection test (T_PCItype) <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7.10 4.CTC_2.3 \u2013 TL Error detection test (T_PCItype) using error bit <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 7.11 4.CTC_2.4 \u2013 Master node \u2013 TL Error detection test (T_PCI_DL) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 7.12 4.CTC_2.5 \u2013 Slave node \u2013 TL Error detection test (T_PCI_DL) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7.13 4.CTC_2.6 \u2013 TL Error detection test (T_PCI_DL) using error bit <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.14 4.CTC_2.7 \u2013 Master node \u2013 TL Error detection test (T_PCI_DLext) <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.15 4.CTC_2.8 \u2013 Slave node \u2013 TL Error detection test (T_PCI_DLext) <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 7.16 4.CTC_2.9 \u2013 TL Error detection test (T_PCI_DLext) using error bit <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 8 Network layer conformance test 8.1 General 8.2 3.CTC_3.1 \u2013 Master node \u2013 N_PDU specification test (N_NAD) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 8.3 3.CTC_3.2 \u2013 Slave node \u2013 N_PDU specification test (N_NAD) <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 8.4 3.CTC_3.3 \u2013 Reception logic test (in the case of T_PID = 1F16 and N_NAD = 0016) <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 8.5 3.CTC_4.1 \u2013 Master node \u2013 NL error detection (N_As timeout) 8.6 3.CTC_4.2 \u2013 Slave node \u2013 NL error detection (N_As timeout) <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Road vehicles. Clock extension peripheral interface (CXPI) – Transport and network layer conformance test plan<\/b><\/p>\n |