{"id":363547,"date":"2024-10-20T01:46:14","date_gmt":"2024-10-20T01:46:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-622222021\/"},"modified":"2024-10-26T02:46:22","modified_gmt":"2024-10-26T02:46:22","slug":"bsi-pd-iec-tr-622222021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-622222021\/","title":{"rendered":"BSI PD IEC TR 62222:2021"},"content":{"rendered":"

This document describes the test methods for various parameters relating to the reaction to fire properties of metallic and optical fibre communications cables. The parameters have particular importance for cables intended to be installed within buildings and other structures.<\/p>\n

This document also maps the test methods and associated limits applied to the fire hazards created by particular installation conditions and which can be referenced by other international, regional and national standards. For example, it is important that compliance with the requirements and recommendations for installation methods in ISO\/IEC 14763-2 taking into consideration this document improve safety concerning fire.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions <\/td>\n<\/tr>\n
18<\/td>\n3.2 Abbreviated terms
4 Communications cabling in buildings
4.1 Installations and associated fire danger <\/td>\n<\/tr>\n
20<\/td>\n4.2 Mitigation of fire hazards
4.2.1 Balanced approach
4.2.2 Fire hazard management
Tables
Table 1 \u2013 Traditional ranking of fire hazards <\/td>\n<\/tr>\n
21<\/td>\n4.2.3 Compartmentation
5 Fire hazard
5.1 Fire hazard considerations <\/td>\n<\/tr>\n
23<\/td>\n5.2 Performance assessment <\/td>\n<\/tr>\n
25<\/td>\n6 Test methods
6.1 Review
6.2 NFPA 262
Table 2 \u2013 Cable fire performance test methods
Table 3 \u2013 Severity <\/td>\n<\/tr>\n
26<\/td>\n6.3 EN 50399
6.4 IEC 60332-3 (all parts) <\/td>\n<\/tr>\n
27<\/td>\n6.5 UL 1666
6.6 UL 1685 and CSA FT4 <\/td>\n<\/tr>\n
28<\/td>\n6.7 Other considerations
6.7.1 Sample selection
6.7.2 Cable mounting
6.7.3 Conditioned environment
6.7.4 Reference scenario
6.8 Test method conclusions <\/td>\n<\/tr>\n
29<\/td>\n7 Fire performance
7.1 Parameters
7.2 Heat <\/td>\n<\/tr>\n
30<\/td>\n7.3 Effluent smoke
Table 4 \u2013 Examples of materials for communication cables
Table 5 \u2013 Heat requirements of EN 13501-6 <\/td>\n<\/tr>\n
31<\/td>\n7.4 Propagation
7.5 Ignitability
7.6 Damaging effects of fire effluents
7.7 Flaming droplets
7.8 Toxicity
8 Legislation and regulation examples
Table 6 \u2013 Smoke requirements comparisons <\/td>\n<\/tr>\n
32<\/td>\nTable 7 \u2013 Class structure of EN 13501-6 <\/td>\n<\/tr>\n
34<\/td>\nAnnex A (informative)Typical communication cable installations
Figure A.1 \u2013 Typical installation locations <\/td>\n<\/tr>\n
35<\/td>\nAnnex B (informative)Fire hazards\/installations\/applications\/test methodsfor communication cables in buildings
Table B.1 \u2013 Fire hazards\/installations\/applications\/test methodsfor communication cables in buildings <\/td>\n<\/tr>\n
36<\/td>\nAnnex C (informative)Review of test methods
Table C.1 \u2013 Ignitability <\/td>\n<\/tr>\n
37<\/td>\nTable C.2 \u2013 Vertical tests <\/td>\n<\/tr>\n
40<\/td>\nTable C.3 \u2013 Horizontal tests for forced air systems <\/td>\n<\/tr>\n
41<\/td>\nTable C.4 \u2013 Indirect measurement of smoke <\/td>\n<\/tr>\n
42<\/td>\nAnnex D (informative)Fire performance requirements
Table D.1 \u2013 Fire performance requirements
Table D.2 \u2013 Single cable burn test <\/td>\n<\/tr>\n
43<\/td>\nAnnex E (informative)Recent project for regulation \u2013 The FIPEC project <\/td>\n<\/tr>\n
44<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fire performance of communication cables installed in buildings<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2021<\/td>\n48<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":363556,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[631,2641],"product_tag":[],"class_list":{"0":"post-363547","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-120-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/363547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/363556"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=363547"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=363547"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=363547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}