{"id":376579,"date":"2024-10-20T02:48:45","date_gmt":"2024-10-20T02:48:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61326-12021-tc\/"},"modified":"2024-10-26T04:58:37","modified_gmt":"2024-10-26T04:58:37","slug":"bs-en-iec-61326-12021-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61326-12021-tc\/","title":{"rendered":"BS EN IEC 61326-1:2021 – TC"},"content":{"rendered":"

IEC 61326-1:2020 is available as IEC 61326-1:2020 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326:2020 specifies requirements for immunity and emissions regarding electro\u00acmagnetic compatibility (EMC) for electrical equipment, operating from a supply or battery of less than 1 000 V AC or 1 500 V DC or from the circuit being measured. Equipment intended for professional, industrial-process, industrial-manufacturing and educational use is covered by this part. It includes equipment and computing devices for – measurement and test; – control; – LABORATORY use; – accessories intended for use with the above (such as sample handling equipment), intended to be used in industrial and non-industrial locations.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\ncompares BS EN IEC 61326-1:2021 <\/td>\n<\/tr>\n
2<\/td>\nTRACKED CHANGES
Text example 1 \u2014 indicates added text (in green) <\/td>\n<\/tr>\n
3<\/td>\nContractual and legal considerations
Compliance with a British Standard cannot confer immunity from legal obligations.
Amendments\/corrigenda issued since publication
Date Text affected <\/td>\n<\/tr>\n
4<\/td>\nElectrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements <\/td>\n<\/tr>\n
5<\/td>\nForeword European foreword
Endorsement notice <\/td>\n<\/tr>\n
8<\/td>\nAnnex ZZ
(informative) <\/td>\n<\/tr>\n
11<\/td>\nINTERNATIONAL ELECTROTECHNICAL COMMISSION <\/td>\n<\/tr>\n
13<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
14<\/td>\nELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE \u2013 EMC REQUIREMENTS \u2013
1 Scope <\/td>\n<\/tr>\n
15<\/td>\n2 Normative references <\/td>\n<\/tr>\n
16<\/td>\n3 Terms and, definitions and abbreviations
3.1 Terms and definitions
3.13.1.1 <\/td>\n<\/tr>\n
17<\/td>\n3.23.1.2
3.33.1.3
3.43.1.4
3.5
3.63.1.5
3.73.1.6
3.83.1.7
3.93.1.8
3.103.1.9 <\/td>\n<\/tr>\n
18<\/td>\n3.113.1.10
Figure 1 \u2013 Examples of ports
3.123.1.12
3.133.1.13
3.1.14
3.1.15 <\/td>\n<\/tr>\n
19<\/td>\n3.1.16
3.1.17
3.1.18
3.2 Abbreviations
4 General <\/td>\n<\/tr>\n
20<\/td>\n5 EMC test plan
5.1 General
5.2 Configuration of EUT during testing
5.2.2 Composition of EUT
5.2.3 Assembly of EUT
5.2.6 Cabling and earthing (grounding) <\/td>\n<\/tr>\n
21<\/td>\n5.3 Operation conditions of EUT during testing
5.3.2 Environmental conditions
5.3.3 EUT software during test
5.5 Test description
6 Immunity requirements
6.1 Conditions during the tests
6.2 Immunity test requirements <\/td>\n<\/tr>\n
22<\/td>\nTable 1 \u2013 Immunity test requirements for equipment <\/td>\n<\/tr>\n
27<\/td>\n6.3 Random aspects
6.4 Performance criteria
6.4.2 Performance criterion A
6.4.3 Performance criterion B <\/td>\n<\/tr>\n
28<\/td>\n6.4.4 Performance criterion C
7 Emission requirements
7.1 Conditions during measurements
7.2 Emission limits <\/td>\n<\/tr>\n
29<\/td>\n8 Test results and test report
9 Instructions for use <\/td>\n<\/tr>\n
30<\/td>\nAnnex A
(normative) <\/td>\n<\/tr>\n
31<\/td>\nAnnex B
(informative)
B.1 General
B.2 Risk analysis
B.3 Risk assessment <\/td>\n<\/tr>\n
33<\/td>\nBibliography <\/td>\n<\/tr>\n
36<\/td>\nundefined <\/td>\n<\/tr>\n
39<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
41<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
43<\/td>\nFOREWORD <\/td>\n<\/tr>\n
45<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
46<\/td>\n1 Scope <\/td>\n<\/tr>\n
47<\/td>\n2 Normative references <\/td>\n<\/tr>\n
48<\/td>\n3 Terms, definitions and abbreviations
3.1 Terms and definitions <\/td>\n<\/tr>\n
50<\/td>\nFigure 1 \u2013 Examples of ports <\/td>\n<\/tr>\n
51<\/td>\n3.2 Abbreviations
4 General
5 EMC test plan
5.1 General <\/td>\n<\/tr>\n
52<\/td>\n5.2 Configuration of EUT during testing
5.2.1 General
5.2.2 Composition of EUT
5.2.3 Assembly of EUT
5.2.4 I\/O ports
5.2.6 Cabling and earthing (grounding)
5.3 Operation conditions of EUT during testing
5.3.1 Operation modes <\/td>\n<\/tr>\n
53<\/td>\n5.3.2 Environmental conditions
5.3.3 EUT software during test
5.4 Specification of functional performance
5.5 Test description
6 Immunity requirements
6.1 Conditions during the tests
6.2 Immunity test requirements <\/td>\n<\/tr>\n
54<\/td>\nTable 1 \u2013 Immunity test requirements for equipment intended to be used in a basic electromagnetic environment <\/td>\n<\/tr>\n
55<\/td>\nTable 2 \u2013 Immunity test requirements for equipment intended to be used in an industrial electromagnetic environment <\/td>\n<\/tr>\n
56<\/td>\n6.3 Random aspects
Table 3 \u2013 Immunity test requirements for equipment intended to be used in a controlled electromagnetic environment <\/td>\n<\/tr>\n
57<\/td>\n6.4 Performance criteria
6.4.1 General
6.4.2 Performance criterion A
6.4.3 Performance criterion B
6.4.4 Performance criterion C <\/td>\n<\/tr>\n
58<\/td>\n7 Emission requirements
7.1 Conditions during measurements
7.2 Emission limits
8 Test results and test report <\/td>\n<\/tr>\n
59<\/td>\n9 Instructions for use <\/td>\n<\/tr>\n
60<\/td>\nAnnex A (normative) Immunity test requirements for portable test and measurement equipment powered by battery or from the circuit being measured
Table A.1 \u2013 Immunity test requirements for portable test and measurement equipment <\/td>\n<\/tr>\n
61<\/td>\nAnnex B (informative) Guide for analysis and assessment for electromagnetic compatibility <\/td>\n<\/tr>\n
63<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. Electrical equipment for measurement, control and laboratory use. EMC requirements – General requirements<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2021<\/td>\n64<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":376589,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[285,2641],"product_tag":[],"class_list":{"0":"post-376579","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-17-220-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/376579","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/376589"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=376579"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=376579"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=376579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}