{"id":398243,"date":"2024-10-20T04:34:45","date_gmt":"2024-10-20T04:34:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1547-2018-3\/"},"modified":"2024-10-26T08:23:03","modified_gmt":"2024-10-26T08:23:03","slug":"ieee-1547-2018-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1547-2018-3\/","title":{"rendered":"IEEE 1547-2018"},"content":{"rendered":"

Revision Standard – Active. The technical specifications for, and testing of, the interconnection and interoperability between utility electric power systems (EPSs) and distributed energy resources (DERs) are the focus of this standard. It provides requirements relevant to the performance, operation, testing, safety considerations, and maintenance of the interconnection. It also includes general requirements, response to abnormal conditions, power quality, islanding, and test specifications and requirements for design, production, installation evaluation, commissioning, and periodic tests. The stated requirements are universally needed for interconnection of DER, including synchronous machines, induction machines, or power inverters\/converters and will be sufficient for most installations. The criteria and requirements are applicable to all DER technologies interconnected to EPSs at typical primary and\/or secondary distribution voltages. Installation of DER on radial primary and secondary distribution systems is the main emphasis of this document, although installation of DERs on primary and secondary network distribution systems is considered. This standard is written considering that the DER is a 60 Hz source.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 1547-2018 Front Cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nAcknowledgements
Participants <\/td>\n<\/tr>\n
11<\/td>\nIntroduction <\/td>\n<\/tr>\n
13<\/td>\nContents <\/td>\n<\/tr>\n
16<\/td>\n1. Overview
1.1 General
1.2 Scope <\/td>\n<\/tr>\n
17<\/td>\n1.3 Purpose
1.4 General remarks and limitations <\/td>\n<\/tr>\n
21<\/td>\n1.5 Conventions for word usage and notes to text, tables and figures
2. Normative references <\/td>\n<\/tr>\n
22<\/td>\n3. Definitions and acronyms
3.1 Definitions <\/td>\n<\/tr>\n
27<\/td>\n3.2 Acronyms <\/td>\n<\/tr>\n
28<\/td>\n4. General interconnection technical specifications and performance requirements
4.1 Introduction <\/td>\n<\/tr>\n
29<\/td>\n4.2 Reference points of applicability (RPA) <\/td>\n<\/tr>\n
30<\/td>\n4.3 Applicable voltages <\/td>\n<\/tr>\n
31<\/td>\n4.4 Measurement accuracy <\/td>\n<\/tr>\n
32<\/td>\n4.5 Cease to energize performance requirement
4.6 Control capability requirements
4.6.1 Capability to disable permit service
4.6.2 Capability to limit active power <\/td>\n<\/tr>\n
33<\/td>\n4.6.3 Execution of mode or parameter changes
4.7 Prioritization of DER responses <\/td>\n<\/tr>\n
34<\/td>\n4.8 Isolation device
4.9 Inadvertent energization of the Area EPS
4.10 Enter service
4.10.1 Introduction
4.10.2 Enter service criteria
4.10.3 Performance during entering service <\/td>\n<\/tr>\n
35<\/td>\n4.10.4 Synchronization <\/td>\n<\/tr>\n
36<\/td>\n4.11 Interconnect integrity
4.11.1 Protection from electromagnetic interference (EMI)
4.11.2 Surge withstand performance
4.11.3 Paralleling device
4.12 Integration with Area EPS grounding
4.13 Exemptions for emergency systems and standby DER
4.13.1 Exemptions for emergency systems <\/td>\n<\/tr>\n
37<\/td>\n4.13.2 Exemptions for standby DER
5. Reactive power capability and voltage\/power control requirements
5.1 Introduction <\/td>\n<\/tr>\n
38<\/td>\n5.2 Reactive power capability of the DER <\/td>\n<\/tr>\n
39<\/td>\n5.3 Voltage and reactive power control
5.3.1 General
5.3.2 Constant power factor mode
5.3.3 Voltage-reactive power mode <\/td>\n<\/tr>\n
41<\/td>\n5.3.4 Active power-reactive power mode
5.3.5 Constant reactive power mode <\/td>\n<\/tr>\n
42<\/td>\n5.4 Voltage and active power control
5.4.1 General
5.4.2 Voltage-active power mode <\/td>\n<\/tr>\n
43<\/td>\n6. Response to Area EPS abnormal conditions
6.1 Introduction <\/td>\n<\/tr>\n
44<\/td>\n6.2 Area EPS faults and open phase conditions
6.2.1 Area EPS faults
6.2.2 Open phase conditions
6.3 Area EPS reclosing coordination <\/td>\n<\/tr>\n
45<\/td>\n6.4 Voltage
6.4.1 Mandatory voltage tripping requirements <\/td>\n<\/tr>\n
47<\/td>\n6.4.2 Voltage disturbance ride-through requirements <\/td>\n<\/tr>\n
55<\/td>\n6.5 Frequency
6.5.1 Mandatory frequency tripping requirements <\/td>\n<\/tr>\n
56<\/td>\n6.5.2 Frequency disturbance ride-through requirements <\/td>\n<\/tr>\n
61<\/td>\n6.6 Return to service after trip <\/td>\n<\/tr>\n
62<\/td>\n7. Power quality
7.1 Limitation of dc injection
7.2 Limitation of voltage fluctuations induced by the DER
7.2.1 General
7.2.2 Rapid voltage changes (RVC) <\/td>\n<\/tr>\n
63<\/td>\n7.2.3 Flicker
7.3 Limitation of current distortion <\/td>\n<\/tr>\n
64<\/td>\n7.4 Limitation of overvoltage contribution
7.4.1 Limitation of overvoltage over one fundamental frequency period <\/td>\n<\/tr>\n
65<\/td>\n7.4.2 Limitation of cumulative instantaneous overvoltage <\/td>\n<\/tr>\n
66<\/td>\n8. Islanding
8.1 Unintentional islanding
8.1.1 General
8.1.2 Conditional extended clearing time
8.1.3 Area EPS with automatic reclosing
8.2 Intentional islanding
8.2.1 General <\/td>\n<\/tr>\n
67<\/td>\n8.2.2 Scheduled intentional islands
8.2.3 Unscheduled intentional islands
8.2.4 Conditions for unscheduled transition to intentional island
8.2.5 Transition of an intentional island from the Area EPS
8.2.6 Reconnection of an intentional island to the Area EPS
8.2.7 Adjustments to DER settings <\/td>\n<\/tr>\n
68<\/td>\n8.2.8 DER categories for intentional islands
9. DER on distribution secondary grid\/area\/street (grid) networks and spot networks
9.1 Network protectors and automatic transfer scheme requirements <\/td>\n<\/tr>\n
69<\/td>\n9.2 Distribution secondary grid networks
9.3 Distribution secondary spot networks <\/td>\n<\/tr>\n
70<\/td>\n10. Interoperability, information exchange, information models, and protocols
10.1 Interoperability requirements
10.2 Monitoring, control, and information exchange requirements
10.3 Nameplate information <\/td>\n<\/tr>\n
71<\/td>\n10.4 Configuration information
10.5 Monitoring information <\/td>\n<\/tr>\n
72<\/td>\n10.6 Management information
10.6.1 General
10.6.2 Constant power factor mode parameters
10.6.3 Voltage-reactive power mode parameters <\/td>\n<\/tr>\n
73<\/td>\n10.6.4 Active power-reactive power mode parameters
10.6.5 Constant reactive power mode parameters
10.6.6 Voltage-active power mode parameters <\/td>\n<\/tr>\n
74<\/td>\n10.6.7 Voltage trip and momentary cessation parameters
10.6.8 Frequency trip parameters
10.6.9 Frequency droop parameters <\/td>\n<\/tr>\n
75<\/td>\n10.6.10 Enter service
10.6.11 Cease to energize and trip
10.6.12 Limit maximum active power <\/td>\n<\/tr>\n
76<\/td>\n10.7 Communication protocol requirements
10.8 Communication performance requirements <\/td>\n<\/tr>\n
77<\/td>\n10.9 Cyber security requirements
11. Test and verification requirements
11.1 Introduction <\/td>\n<\/tr>\n
78<\/td>\n11.2 Definition of test and verification methods
11.2.1 General
11.2.2 Type tests
11.2.3 Production tests <\/td>\n<\/tr>\n
79<\/td>\n11.2.4 DER evaluation
11.2.5 Commissioning tests and verifications <\/td>\n<\/tr>\n
80<\/td>\n11.2.6 Periodic tests and verifications
11.3 Full and partial conformance testing and verification
11.3.1 General <\/td>\n<\/tr>\n
81<\/td>\n11.3.2 DER that shall meet requirements at the PCC <\/td>\n<\/tr>\n
88<\/td>\n11.3.3 DER that shall meet requirements at the PoC <\/td>\n<\/tr>\n
95<\/td>\n11.4 Fault current characterization
11.4.1 General
11.4.2 Electronically coupled DER
11.4.3 Synchronous and induction generator DER <\/td>\n<\/tr>\n
96<\/td>\nAnnex A (informative) Bibliography <\/td>\n<\/tr>\n
99<\/td>\nAnnex B (informative) Guidelines for DER performance category assignment
B.1 Introduction
B.2 Background <\/td>\n<\/tr>\n
100<\/td>\nB.3 Normal and abnormal performance category standard approach
B.3.1 General <\/td>\n<\/tr>\n
101<\/td>\nB.3.2 Normal performance categories (Clause 5) <\/td>\n<\/tr>\n
102<\/td>\nB.3.3 Abnormal performance categories (Clause 6) <\/td>\n<\/tr>\n
103<\/td>\nB.4 Performance category assignment
B.4.1 General
B.4.2 DER attribute groupings
B.4.3 Performance category assignment criteria <\/td>\n<\/tr>\n
108<\/td>\nAnnex C (informative) DER intentional and microgrid island system configurations
C.1 Introduction <\/td>\n<\/tr>\n
109<\/td>\nC.2 Connecting DER not designed for intentional island or microgrid operation <\/td>\n<\/tr>\n
110<\/td>\nAnnex D (informative) DER communication and information concepts and guidelines
D.1 Introduction
D.2 General principles
D.2.1 General
D.2.2 Scope
D.2.3 Standardized local DER communication interface <\/td>\n<\/tr>\n
111<\/td>\nD.2.4 Information model harmonization <\/td>\n<\/tr>\n
112<\/td>\nD.3 Communication protocols
D.3.1 General
D.3.2 IEEE Std 2030.5 (SEP2)
D.3.3 IEEE Std 1815 (DNP3)
D.3.4 SunSpec Modbus
D.3.5 IEC 61850
D.4 Cyber security
D.4.1 DER security requirements
D.4.2 DER physical security <\/td>\n<\/tr>\n
113<\/td>\nD.4.3 DER front panel security
D.4.4 DER network security
D.4.5 Local DER communication interface security <\/td>\n<\/tr>\n
114<\/td>\nD.5 Related standards
D.5.1 IEC 62351-12
D.5.2 IEEE Std 1547.2 <\/td>\n<\/tr>\n
115<\/td>\nD.5.3 IEEE Std 1547.3
D.5.4 IEEE Std 2030\u00ae
D.5.5 NISTIR 7628 <\/td>\n<\/tr>\n
116<\/td>\nAnnex E (informative) Basis for ride-through of consecutive voltage disturbances
E.1 Introduction
E.2 Faults, fault protection, and reclosing <\/td>\n<\/tr>\n
121<\/td>\nE.3 Unrelated faults
E.4 Intermittent faults
E.5 Voltage oscillations <\/td>\n<\/tr>\n
122<\/td>\nAnnex F (informative) Discussion of testing and verification requirements at PCC or PoC <\/td>\n<\/tr>\n
124<\/td>\nAnnex G (informative) Power quality (PQ) clause concepts and guidelines
G.1 Introduction
G.2 Rapid voltage change (RVC) limits <\/td>\n<\/tr>\n
126<\/td>\nG.3 Flicker limits <\/td>\n<\/tr>\n
127<\/td>\nG.4 Current distortion limits
G.4.1 Challenges of field testing for compliance <\/td>\n<\/tr>\n
128<\/td>\nG.4.2 Background voltage distortion challenges <\/td>\n<\/tr>\n
129<\/td>\nG.5 Limitation of overvoltage
G.6 Related standards <\/td>\n<\/tr>\n
130<\/td>\nAnnex H (informative) Figures illustrating general interconnection technical specifications and performance requirements of Clause 4 to Clause 6
H.1 Informative figures related to 4.2 [Reference points of applicability (RPA)] <\/td>\n<\/tr>\n
131<\/td>\nH.2 Informative figures related to Clause 5 (Reactive power capability and voltage\/power control requirements) <\/td>\n<\/tr>\n
134<\/td>\nH.3 Informative figures related to Clause 6 (Response to Area EPS abnormal conditions) <\/td>\n<\/tr>\n
138<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2018<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":398247,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-398243","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/398243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/398247"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=398243"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=398243"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=398243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}