{"id":449345,"date":"2024-10-20T09:02:10","date_gmt":"2024-10-20T09:02:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-92-2024\/"},"modified":"2024-10-26T16:54:16","modified_gmt":"2024-10-26T16:54:16","slug":"nfpa-92-2024","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-92-2024\/","title":{"rendered":"NFPA 92 2024"},"content":{"rendered":"

Help manage smoke more effectively in the event of a fire. NFPA 92, Standard for Smoke Control Systems, covers the design, installation, testing, and maintenance of all types of smoke control systems, including design fundamentals, smoke management calculation procedures, building equipment and controls, smoke control system documentation, and more. The 2024 edition includes: Revised definition for dampers in Chapter 3 Updated terminology for the listing of control equipment for smoke control systems in Chapter 6 Revised requirements for period testing in Chapter 8 Added Annex A material on maintaining tenability in communication spaces<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nImportant Notices and Disclaimers <\/td>\n<\/tr>\n
3<\/td>\nAdditional Important Notices and Disclaimers <\/td>\n<\/tr>\n
8<\/td>\nChapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Retroactivity.
1.4 Equivalency.
1.5 Units and Formulas. (Reserved)
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications. <\/td>\n<\/tr>\n
9<\/td>\n2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions. <\/td>\n<\/tr>\n
11<\/td>\nChapter 4 Design Fundamentals
4.1 Design Objectives.
4.2 Design Basis.
4.3 Design Approaches.
4.4 Design Criteria. <\/td>\n<\/tr>\n
12<\/td>\n4.5 System Operation. <\/td>\n<\/tr>\n
13<\/td>\n4.6 Stairwell Pressurization Systems.
4.7 Elevator Pressurization Systems.
4.8 Zoned Smoke Control. <\/td>\n<\/tr>\n
14<\/td>\n4.9 Combination of Systems.
4.10 Vestibules.
4.11 Doors.
Chapter 5 Smoke Management Calculation Procedures
5.1 Introduction.
5.2 Design Fire. <\/td>\n<\/tr>\n
15<\/td>\n5.3 Mass Consumption. <\/td>\n<\/tr>\n
16<\/td>\n5.4 Smoke Layer Calculations.
5.5 Rate of Smoke Mass Production. <\/td>\n<\/tr>\n
19<\/td>\n5.6 Number of Exhaust Inlets. <\/td>\n<\/tr>\n
20<\/td>\n5.7 Volumetric Flow Rate.
5.8 Density of Smoke.
5.9 Varying Cross-Sectional Geometries and Complex Geometries.
5.10 Opposed Airflow. <\/td>\n<\/tr>\n
22<\/td>\n5.11 Scaling Laws.
Chapter 6 Building Equipment and Controls
6.1 General.
6.2 Heating, Ventilating, and Air-Conditioning (HVAC) Equipment.
6.3 Smoke Dampers.
6.4 Smoke Control Systems. <\/td>\n<\/tr>\n
25<\/td>\n6.5 Energy Management.
6.6 Materials.
6.7 Electric Services Installation.
Chapter 7 Smoke Control System Documentation
7.1 Documentation Required.
7.2 Detailed Design Report.
7.3 Operations and Maintenance Manual. <\/td>\n<\/tr>\n
26<\/td>\nChapter 8 Testing
8.1 General.
8.2 Preliminary Building Inspections.
8.3 Component System Testing.
8.4 Acceptance Testing. <\/td>\n<\/tr>\n
28<\/td>\n8.5 Testing Documentation.
8.6 Periodic TestingInspection, Testing, and Maintenance.
8.7 Modifications. <\/td>\n<\/tr>\n
29<\/td>\nAnnex A Explanatory Material <\/td>\n<\/tr>\n
51<\/td>\nAnnex B Predicting the Rate of Heat Release of Fires <\/td>\n<\/tr>\n
62<\/td>\nAnnex C Computer-Based Models for Atria and Malls <\/td>\n<\/tr>\n
68<\/td>\nAnnex D Additional Design Objectives <\/td>\n<\/tr>\n
71<\/td>\nAnnex E Stratification of Smoke <\/td>\n<\/tr>\n
72<\/td>\nAnnex F Types of Stairwell Pressurization Systems <\/td>\n<\/tr>\n
74<\/td>\nAnnex G HVAC Air-Handling System Types <\/td>\n<\/tr>\n
75<\/td>\nAnnex H Firefighters\u2019 Smoke Control Station (FSCS) Considerations <\/td>\n<\/tr>\n
76<\/td>\nAnnex I Information on Testing for Leakage Between Smoke Zones <\/td>\n<\/tr>\n
77<\/td>\nAnnex J Advisory Information on Acceptance Testing <\/td>\n<\/tr>\n
78<\/td>\nAnnex K Example Problems Illustrating the Use of Equations <\/td>\n<\/tr>\n
82<\/td>\nAnnex L Comparison of Equations <\/td>\n<\/tr>\n
85<\/td>\nAnnex M Tenability <\/td>\n<\/tr>\n
88<\/td>\nAnnex N Informational References <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 92: Standard for Smoke Control Systems<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2024<\/td>\n97<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":449350,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-449345","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/449345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/449350"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=449345"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=449345"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=449345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}